      Achieving a healthy indoor environment by using an emissions barrier for stopping spread of chemicals from building into the indoor air

      Preprint
      research-article
      This is not the latest version for this article. If you want to read the latest version, click here.
      Bookmark

            Revision notes

            Pawel

            Introduction: 

            Airborne particles released from the building construction may be removed by using portable air cleaners with mechanical air filtration (HEPA etc) - Please provide HEPA abbreviation for the clarification. Has been done

            Results 1st installation:

            Also, the mouldy odour disappeared in the bedroom following the cTrap installation.  Is that a personal statement of the authors? If yes, please indicate that in the paragraph. Has been clarified

            General comment: Please keep air concentration unites consistant with the table 1 (µg/m3 not µg/m3). All air concentration unites should ideally be presented or as per ng or µg /m3 for consistency. Has been corrected

            Results: 2nd  installation:

            There was a disturbing smell inside the building which persisted even after the tar had been removed. If possible, please provide more information about a smell. Has been done

            Table 1:

            a) n.d. for chloroanisoles. Please provide the abbreviation of n.d. If not detected, please provide a limit of detection (LOD) for this compound. Information has been added

            b) The unit of µg/m3  is not applicable for the 'emmisions'  table row but for 'without cTrap' and ' with cTrap' rows. Please modify it for the clarification. Has been corrected

            References 

            Kolarik, J., and Wargocki P. (2010). Can a photocatalytic air purifier be used to improve the perceived air quality indoors? Indoor Air 20, 255-262. Markowicz, P. and Larsson, L. (2012). The surface emissions trap: A new approach in indoor air purification. J. Microbiol. Methods 91, 290-294.\

            Please separate both references Has been done.

            Ola

            The manuscript proposes unique methodology for isolation/encapsulation of indoor pollution sources if it is impossible or too expensive to remove them. Especially useful when experiencing adverse health effects from moisture damage buildings and when reparation needs to be done quickly. What makes this research very interesting are documented practical interventions in existing troublesome indoor environments, leading to significant improvements in the air quality and symptoms of the tenants.

            Introduction, Second paragraph

            I really like comprehensive information about indoor air cleaning techniques and harmfulness of devices using UV light and ozone for destroying microorganisms and converting airborne VOCs.

            Methods

            Some more information/citations about analytical methodology would be appreciated. We have added that the analyses were made by a commercial laboratory viz Eurofins Pegasuslab Ltd, Uppsala, Sweden.

            Results 1

            Authors mention odour assessment in a few places in the manuscript. It would be interesting to know if they used a special smell validation protocol and how many persons took part in the test. Information has been added.

            “The ceiling, walls and floor in the bedroom (as well as the doorway between the bedroom and the living room), but not in the living-room.  were covered with the cTrap cloth.  Subsequently, air sampling for chlorophenols/chloroanisoles was carried out simultaneously in both rooms.”

            How long did it take between covering the surfaces with the cTrap and subsequent sampling? Was it an adequate time to reach the equilibrium? It took a few hours. We agree that long term results cannot be evaluated from this experiment; a comment has been added under Discussion.

            Results 2

            “The air concentrations of PAH were 1726 ng/m3 air. There was a disturbing smell inside the building which persisted even after the tar had been removed. Then, the cTrap cloth was installed on about 75 percent of the wall surface. The smell disappeared and the PAH air concentrations decreased to 139 ng/m3, thus corresponding to a reduction of 92% (Table 1).”

            Even tough, the reduction of PAHs concentration is huge, is it enough to justify the installation of the clothe? Please provide exposure limits for occupational conditions or, if possible, indoor environments. Exposure limits differ very much for the different PAH. In general, if the odour complaints disappear then it is assumed that the PAH problem has been solved.

            Likewise, for other substances mentioned in the Table 1.

             Results 3

            “3 months after cTrap had been installed the air concentration was 1.5 μg /m3 (Table 1), a value which persisted in a follow-up study 6 years after the installation -and the residents still reported no symptoms.”

            Long term studies are very much appreciated!

            Discussion

            Please provide also some more resent references in the first paragraph. Has been done.

            Abstract

            An emissions barrier was used in premises with indoor air complaints due to emissions from the buildings in question. The emissions comprised chlorophenols/chloroanisoles and polycyclic aromatic hydrocarbons (PAH) from treated wood, and volatile organic compounds (VOC), mainly 2-ethylhexanol, from PVC flooring and the glue used to paste the flooring onto a concrete slab. Attaching the barrier at the surfaces from where the emissions were spread (floor, walls, ceiling) resulted in a fresh and odour-free indoor air. We conclude that using an emissions barrier in buildings made unhealthy by moisture is an efficient way of restoring a pleasant and healthy indoor air.

            Content

            Author and article information

            Journal
            UCL Open: Environment Preprint
            UCL Press
            14 January 2022
            Affiliations
            [1 ] cTrap Ltd, Prästavägen 12, 224 80 Lund, Sweden
            [2 ] Lund University
            Author notes
            Author information
            https://orcid.org/0000-0002-5847-7528
            Article
            10.14324/111.444/000099.v2
            978b636b-1d84-4cc0-980c-d647801f9ae7

            This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY) 4.0 https://creativecommons.org/licenses/by/4.0/, which permits unrestricted use, distribution and reproduction in any medium, provided the original author and source are credited.

            History
            : 14 October 2021
            : 20 January 2022

            The datasets generated during and/or analysed during the current study are available from the corresponding author on reasonable request.
            Materials technology,Historic preservation,Civil engineering,Public health
            Emissions barrier,Adsorbent,Healthy buildings,Restoration,Sustainability in architecture and the built environment,Pollution and health,Sustainability,People and their environment

            Comments

            all comments and questions have been answered 

            2022-01-20 20:59 UTC
            +1

            all comments and questions have been answered 

            2022-01-20 20:59 UTC
            +1

            all comments and questions have been answered 

            2022-01-20 20:59 UTC
            +1

            all comments and questions have been answered 

            2022-01-20 20:59 UTC
            +1

            Date: 20 January 2022

            Handling Editor: Dr Yasemin D. Aktas

            Editorial decision: Accept. This revised article has been accepted following peer review and it is suitable for publication in UCL Open: Environment.

            2022-01-20 16:50 UTC
            +1

            All my comments and questions have been answered by authors. 

            2022-01-20 20:59 UTC

            All my comments and questions have been answered by authors. 

            2022-01-20 20:59 UTC

            All my comments and questions have been answered by authors. 

            2022-01-20 20:59 UTC

            Date: 19 Januray 2022

            Handling Editor: Dr Yasemin D. Aktas

            The article has been revised, this article remains a preprint article and peer-review has not been completed. It is under consideration following submission to UCL Open: Environment for open peer review.