          Abstract

          The effects of respiration movements on primary lung cells from patients are investigated on an easy to handle lung-on-a-chip.

          Abstract

          We report a lung-on-a-chip array that mimics the pulmonary parenchymal environment, including the thin alveolar barrier and the three-dimensional cyclic strain induced by breathing movements. The micro-diaphragm used to stretch the alveolar barrier is inspired by the in vivodiaphragm, the main muscle responsible for inspiration. The design of this device aims not only at best reproducing the in vivoconditions found in the lung parenchyma but also at making the device robust and its handling easy. An innovative concept, based on the reversible bonding of the device, is presented that enables accurate control of the concentration of cells cultured on the membrane by easily accessing both sides of the membranes. The functionality of the alveolar barrier could be restored by co-culturing epithelial and endothelial cells that form tight monolayers on each side of a thin, porous and stretchable membrane. We showed that cyclic stretch significantly affects the permeability properties of epithelial cell layers. Furthermore, we also demonstrated that the strain influences the metabolic activity and the cytokine secretion of primary human pulmonary alveolar epithelial cells obtained from patients. These results demonstrate the potential of this device and confirm the importance of the mechanical strain induced by breathing in pulmonary research.

          Related collections

          Most cited references26

          • Record: found
          • Abstract: found
          • Article: not found

          Reconstituting organ-level lung functions on a chip.

          Here, we describe a biomimetic microsystem that reconstitutes the critical functional alveolar-capillary interface of the human lung. This bioinspired microdevice reproduces complex integrated organ-level responses to bacteria and inflammatory cytokines introduced into the alveolar space. In nanotoxicology studies, this lung mimic revealed that cyclic mechanical strain accentuates toxic and inflammatory responses of the lung to silica nanoparticles. Mechanical strain also enhances epithelial and endothelial uptake of nanoparticulates and stimulates their transport into the underlying microvascular channel. Similar effects of physiological breathing on nanoparticle absorption are observed in whole mouse lung. Mechanically active "organ-on-a-chip" microdevices that reconstitute tissue-tissue interfaces critical to organ function may therefore expand the capabilities of cell culture models and provide low-cost alternatives to animal and clinical studies for drug screening and toxicology applications.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            The productivity crisis in pharmaceutical R&D.

            Advances in the understanding of the molecular basis of diseases have expanded the number of plausible therapeutic targets for the development of innovative agents in recent decades. However, although investment in pharmaceutical research and development (R&D) has increased substantially in this time, the lack of a corresponding increase in the output in terms of new drugs being approved indicates that therapeutic innovation has become more challenging. Here, using a large database that contains information on R&D projects for more than 28,000 compounds investigated since 1990, we examine the decline of R&D productivity in pharmaceuticals in the past two decades and its determinants. We show that this decline is associated with an increasing concentration of R&D investments in areas in which the risk of failure is high, which correspond to unmet therapeutic needs and unexploited biological mechanisms. We also investigate the potential variations in productivity with regard to the regional location of companies and find that although companies based in the United States and Europe differ in the composition of their R&D portfolios, there is no evidence of any productivity gap.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Concordance of the toxicity of pharmaceuticals in humans and in animals.

              This report summarizes the results of a multinational pharmaceutical company survey and the outcome of an International Life Sciences Institute (ILSI) Workshop (April 1999), which served to better understand concordance of the toxicity of pharmaceuticals observed in humans with that observed in experimental animals. The Workshop included representatives from academia, the multinational pharmaceutical industry, and international regulatory scientists. The main aim of this project was to examine the strengths and weaknesses of animal studies to predict human toxicity (HT). The database was developed from a survey which covered only those compounds where HTs were identified during clinical development of new pharmaceuticals, determining whether animal toxicity studies identified concordant target organ toxicities in humans. Data collected included codified compounds, therapeutic category, the HT organ system affected, and the species and duration of studies in which the corresponding HT was either first identified or not observed. This survey includes input from 12 pharmaceutical companies with data compiled from 150 compounds with 221 HT events reported. Multiple HTs were reported in 47 cases. The results showed the true positive HT concordance rate of 71% for rodent and nonrodent species, with nonrodents alone being predictive for 63% of HTs and rodents alone for 43%. The highest incidence of overall concordance was seen in hematological, gastrointestinal, and cardiovascular HTs, and the least was seen in cutaneous HT. Where animal models, in one or more species, identified concordant HT, 94% were first observed in studies of 1 month or less in duration. These survey results support the value of in vivo toxicology studies to predict for many significant HTs associated with pharmaceuticals and have helped to identify HT categories that may benefit from improved methods. Copyright 2000 Academic Press.
                Bookmark

                Author and article information

                Journal
                LCAHAM
                Lab on a Chip
                Lab Chip
                Royal Society of Chemistry (RSC)
                1473-0197
                1473-0189
                2015
                2015
                : 15
                : 5
                : 1302-1310
                Affiliations
                [1 ]ARTORG Center for Biomedical Engineering Research
                [2 ]Lung Regeneration Technologies
                [3 ]University of Berne
                [4 ]Switzerland
                [5 ]Graduate School for Cellular and Biomedical Sciences
                [6 ]Division of Thoracic Surgery
                [7 ]University Hospital of Berne
                [8 ]Department of Clinical Research
                [9 ]Division of Pulmonary Medicine
                Article