          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The field of ureteroscopy has undergone a continual evolution since the first ureteroscopes were introduced. Over the past 10 years, we have entered into the digital era of ureteroscopy with both semirigid and flexible options becoming available. The following review looks at the benefits and drawbacks of digital flexible ureteroscopes as well as the current commercially available options.

          Related collections

          Most cited references25

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Comparison of New Single-Use Digital Flexible Ureteroscope Versus Nondisposable Fiber Optic and Digital Ureteroscope in a Cadaveric Model

          Abstract Purpose: To evaluate LithoVue, the new single-use digital flexible ureteroscope, in a human cadaveric model and compare it with a nondisposable fiber optic and digital flexible ureteroscopes. Materials and Methods: LithoVue, a conventional fiber optic, and digital flexible ureteroscopes were each tested in four renal units of recently deceased female cadavers by three surgeons. The following parameters were analyzed: accessibility to the kidney and navigation of the entire collecting system with and without ureteral access sheath (UAS), lower pole access measuring the deflection of the ureteroscope with the working channel empty, and with inside two different baskets and laser fibers. A subjective evaluation of maneuverability and visibility was assessed by each surgeon at the end of every procedure. Results: Kidney access into the Renal unit 1 was not possible without UAS for all ureteroscopes because of noncompliant ureter at the level of sacroiliac joint. The reusable digital ureteroscope was unable to reach one calix of the lower pole and one calix of the upper pole (Renal units 2 and 3) without UAS placement. Lower pole access with baskets and laser fibers was possible for each ureteroscope after UAS placement. No statistically significant differences were detected in angle deflection between ureteroscopes. The digital ureteroscope was preferred for visibility in all procedures: LithoVue for maneuverability in six procedures, fiber optic in five procedures, and the digital ureteroscope in one procedure. Conclusions: LithoVue seems to be comparable with conventional ureteroscopes in terms of visibility and manipulation into the collecting system in fresh human cadavers. Further studies in humans are needed to determine the clinical value of this new instrument.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            A new robot for flexible ureteroscopy: development and early clinical results (IDEAL stage 1-2b).

            An improved armamentarium has had a significant impact on the emerging role of flexible ureteroscopy (FURS) for the management of nephrolithiasis; however, FURS still represents a challenging technique.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Flexible ureteroscopes: a single center evaluation of the durability and function of the new endoscopes smaller than 9Fr.

              Flexible ureteroscopes smaller than 9Fr are widely used in endourology. We systematically evaluated the functional durability of these instruments in the clinical setting. We performed ureteronephroscopy 92 consecutive times in 84 patients at our hospital using a flexible Storz model 11274AA,double dagger Circon-ACMI model AUR-7, section sign Wolf model 7325.172 parallel and Olympus model URF/P3 ureteroscope paragraph sign. Preoperatively and postoperatively we evaluated all flexible ureteroscopes for luminosity, irrigant flow at 100 mm. Hg, number of broken image fibers and active deflection range. During the procedure a record was kept of the duration that the endoscope remained in the urinary tract, average irrigation pressure, method of insertion, various devices used within the working channel, need for lower pole access, and surgeon overall impression of visibility and maneuverability. The luminosity and irrigant flow of all endoscopes remained relatively unchanged during consecutive applications, while active deflection deteriorated 2% to 28%. Endoscopes were used for an average of 3 to 13 hours before they needed repair. The most fragile part of these instruments was the deflection unit. Small diameter flexible ureteroscopes are effective for diagnosing and treating upper urinary tract pathology but improved durability is required. Currently they represent a highly effective but high maintenance means of achieving retrograde access to the ureter and kidney with a need for repair after only 6 to 15 uses.
                Bookmark

                Author and article information

                Journal
                Res Rep Urol
                Res Rep Urol
                Research and Reports in Urology
                Research and Reports in Urology
                Dove Medical Press
                2253-2447
                2017
                27 January 2017
                : 9
                : 19-25
                Affiliations
                Department of Urology, The Ohio State University Wexner Medical Center, Columbus, OH, USA
                Author notes
                Correspondence: Bodo E Knudsen, Department of Urology, The Ohio State University Wexner Medical Center, 915 Olentangy River Rd, Columbus, OH 43212, USA, Tel +1 614 293 9349, Fax +1 614 293 3565, Email Bodo.Knudsen@ 123456osumc.edu
                Article
                rru-9-019
                10.2147/RRU.S104229
                5293503
                28203551
                6e958d14-ea74-4c77-b129-fd2459bb486a
                © 2017 Gridley and Knudsen. This work is published and licensed by Dove Medical Press Limited

                The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License ( http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.

                History
                Categories
                Original Research

                digital,video,flexible ureteroscopy
                digital, video, flexible ureteroscopy

                Comments

                Comment on this article