      Robust High-Dynamic-Range Vector Magnetometry via Nitrogen-Vacancy Centers in Diamond

      Preprint

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We demonstrate a robust, scale-factor-free vector magnetometer, which uses a closed-loop frequency-locking scheme to simultaneously track Zeeman-split resonance pairs of nitrogen-vacancy (NV) centers in diamond. Compared with open-loop methodologies, this technique is robust against fluctuations in temperature, resonance linewidth, and contrast; offers a three-order-of-magnitude increase in dynamic range; and allows for simultaneous interrogation of multiple transition frequencies. By directly detecting the resonance frequencies of NV centers aligned along each of the diamond's four tetrahedral crystallographic axes, we perform full vector reconstruction of an applied magnetic field.

          Related collections

          Most cited references11

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          The nitrogen-vacancy colour centre in diamond

          The nitrogen-vacancy (NV) colour centre in diamond is an important physical system for emergent quantum technologies, including quantum metrology, information processing and communications, as well as for various nanotechnologies, such as biological and sub-diffraction limit imaging, and for tests of entanglement in quantum mechanics. Given this array of existing and potential applications and the almost 50 years of NV research, one would expect that the physics of the centre is well understood, however, the study of the NV centre has proved challenging, with many early assertions now believed false and many remaining issues yet to be resolved. This review represents the first time that the key empirical and ab initio results have been extracted from the extensive NV literature and assembled into one consistent picture of the current understanding of the centre. As a result, the key unresolved issues concerning the NV centre are identified and the possible avenues for their resolution are examined.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            A robust, scanning quantum system for nanoscale sensing and imaging

            Controllable atomic-scale quantum systems hold great potential as sensitive tools for nanoscale imaging and metrology. Possible applications range from nanoscale electric and magnetic field sensing to single photon microscopy, quantum information processing, and bioimaging. At the heart of such schemes is the ability to scan and accurately position a robust sensor within a few nanometers of a sample of interest, while preserving the sensor's quantum coherence and readout fidelity. These combined requirements remain a challenge for all existing approaches that rely on direct grafting of individual solid state quantum systems or single molecules onto scanning-probe tips. Here, we demonstrate the fabrication and room temperature operation of a robust and isolated atomic-scale quantum sensor for scanning probe microscopy. Specifically, we employ a high-purity, single-crystalline diamond nanopillar probe containing a single Nitrogen-Vacancy (NV) color center. We illustrate the versatility and performance of our scanning NV sensor by conducting quantitative nanoscale magnetic field imaging and near-field single-photon fluorescence quenching microscopy. In both cases, we obtain imaging resolution in the range of 20 nm and sensitivity unprecedented in scanning quantum probe microscopy.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              High nitrogen-vacancy density diamonds for magnetometry applications

              Nitrogen-vacancy (NV) centers in millimeter-scale diamond samples were produced by irradiation and subsequent annealing under varied conditions. The optical and spin relaxation properties of these samples were characterized using confocal microscopy, visible and infrared absorption, and optically detected magnetic resonance. The sample with the highest NV- concentration, approximately 16 ppm = 2.8 x 10^{18} cm^{-3}, was prepared with no observable traces of neutrally-charged vacancy defects. The effective transverse spin relaxation time for this sample was T2* = 118(48) ns, predominately limited by residual paramagnetic nitrogen which was determined to have a concentration of 52(7) ppm. Under ideal conditions, the shot-noise limited sensitivity is projected to be ~150 fT/\sqrt{Hz} for a 100 micron-scale magnetometer based on this sample. Other samples with NV- concentrations from .007 to 12 ppm and effective relaxation times ranging from 27 to 291 ns were prepared and characterized.
                Bookmark

                Author and article information

                Journal
                26 February 2018
                Article
                1802.09713
                659bf19c-5cc8-45a6-a577-aab7e085319a

                http://arxiv.org/licenses/nonexclusive-distrib/1.0/

                History
                Custom metadata
                quant-ph cond-mat.mes-hall physics.app-ph physics.ins-det

                Comments

                Comment on this article