19
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Structure and mechanical properties of pincers of lobster (Procambarus clarkii) and crab (Eriocheir Sinensis)

      , , ,
      Journal of the Mechanical Behavior of Biomedical Materials
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The structure and mechanical properties of the pincer exoskeletons (cuticles) of lobster (Procambarus clarkii) and crab (Eriocheir Sinensis) were investigated, respectively. The microstructures and inorganic materials of the pincer exoskeletons were observed and determined using a scanning electron microscope and X-ray diffraction. The mechanical properties of the pincer exoskeletons were evaluated by nano-indentation tests and tensile tests under different conditions. The results showed that the inorganic materials in the lobster claw exoskeleton exhibited an amorphous structure, while those in the crab claw exoskeleton were crystallized as calcium carbonate with a calcite crystal structure and were stable at the temperature below 250 degrees C. The surfaces of the pincers were biologically unsmooth. Many concave valleys with setae near the tip and many convex domes far off the tip were observed on the surface of the lobster pincer, while many micro-spines were seen on the surface of crab pincer. The microstructures of the pincer exoskeleton exhibited highly mineralized chitin-protein fibers arranged in a twisted plywood structure. The surface hardness and elastic modulus of the crab claws were 0.33 GPa and 8.18 GPa, respectively, higher than those of the lobster claw (0.27 and 5.44 GPa). The transition in the mechanical properties and structure between the exocuticle and the endocuticle was discontinuity. The tensile strength of the crab pincer was two times higher than that of the lobster pincer, and the dry specimen was fractured more easily than the fresh specimen.

          Related collections

          Author and article information

          Journal
          Journal of the Mechanical Behavior of Biomedical Materials
          Journal of the Mechanical Behavior of Biomedical Materials
          Elsevier BV
          17516161
          August 2010
          August 2010
          : 3
          : 6
          : 454-463
          Article
          10.1016/j.jmbbm.2010.05.001
          20621028
          ec295f04-4ded-49ad-83a6-6f2bcf7d0427
          © 2010

          https://www.elsevier.com/tdm/userlicense/1.0/

          History

          Comments

          Comment on this article