1
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Effect of thermal control of dry fomites on regulating the survival of human pathogenic bacteria responsible for nosocomial infections

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We monitored the survival of human pathogenic bacteria [ Escherichia coli (ATCC), extended-spectrum β-lactamase-producing E. coli (Clinical isolate), New Delhi metallo-β-lactamase-producing E. coli (clinical isolate), Staphylococcus aureus (ATCC)] on dry materials (vinyl chloride, aluminum, plastic, stainless steel) at distinct temperatures (room temperature or 15°C–37°C). These bacteria favored a lower temperature for their prolonged survival on the dry fomites, regardless of the material type. Interestingly, when mixed with S. aureus, E. coli survived for a longer time at a lower temperature. Cardiolipin, which can promote the survival of S. aureus in harsh environments, had no effect on maintaining the survival of E. coli. Although the trends remained unchanged, adjusting the humidity from 40% to 60% affected the survival of bacteria on dry surfaces. Scanning electron microscopic analysis revealed no morphological differences in these bacteria immediately before or after one day of dry conditions. In addition, ATP assessment, a method used to visualize high-touch surfaces in hospitals, was not effective at monitoring bacterial dynamics. A specialized handrail device fitted with a heater, which was maintained at normal human body core temperature, successfully prohibited the prolonged survival of bacteria [ Enterococcus faecalis (ATCC), E. coli (ATCC), Pseudomonas aeruginosa (ATCC), S. aureus (ATCC), Acinetobacter baumannii (clinical isolate), and Serratia marcescens (clinical isolate)], with the exception of spore-forming Bacillus subtilis (from our laboratory collection) and the yeast-like fungus Candida albicans (from our laboratory collection)] on dry surfaces. Taken together, we concluded that the tested bacteria favor lower temperatures for their survival in dry environments. Therefore, the thermal control of dry fomites has the potential to control bacterial survival on high-touch surfaces in hospitals.

          Related collections

          Most cited references41

          • Record: found
          • Abstract: found
          • Article: not found

          The role of environmental cleaning in the control of hospital-acquired infection.

          S.J Dancer (2009)
          Increasing numbers of hospital-acquired infections have generated much attention over the last decade. The public has linked the so-called 'superbugs' with their experience of dirty hospitals but the precise role of environmental cleaning in the control of these organisms remains unknown. Until cleaning becomes an evidence-based science, with established methods for assessment, the importance of a clean environment is likely to remain speculative. This review will examine the links between the hospital environment and various pathogens, including meticillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, norovirus, Clostridium difficile and acinetobacter. These organisms may be able to survive in healthcare environments but there is evidence to support their vulnerability to the cleaning process. Removal with, or without, disinfectants, appears to be associated with reduced infection rates for patients. Unfortunately, cleaning is often delivered as part of an overall infection control package in response to an outbreak and the importance of cleaning as a single intervention remains controversial. Recent work has shown that hand-touch sites are habitually contaminated by hospital pathogens, which are then delivered to patients on hands. It is possible that prioritising the cleaning of these sites might offer a useful adjunct to the current preoccupation with hand hygiene, since hand-touch sites comprise the less well-studied side of the hand-touch site equation. In addition, using proposed standards for hospital hygiene could provide further evidence that cleaning is a cost-effective intervention for controlling hospital-acquired infection.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            Modern technologies for improving cleaning and disinfection of environmental surfaces in hospitals

            John Boyce (2016)
            Experts agree that careful cleaning and disinfection of environmental surfaces are essential elements of effective infection prevention programs. However, traditional manual cleaning and disinfection practices in hospitals are often suboptimal. This is often due in part to a variety of personnel issues that many Environmental Services departments encounter. Failure to follow manufacturer’s recommendations for disinfectant use and lack of antimicrobial activity of some disinfectants against healthcare-associated pathogens may also affect the efficacy of disinfection practices. Improved hydrogen peroxide-based liquid surface disinfectants and a combination product containing peracetic acid and hydrogen peroxide are effective alternatives to disinfectants currently in widespread use, and electrolyzed water (hypochlorous acid) and cold atmospheric pressure plasma show potential for use in hospitals. Creating “self-disinfecting” surfaces by coating medical equipment with metals such as copper or silver, or applying liquid compounds that have persistent antimicrobial activity surfaces are additional strategies that require further investigation. Newer “no-touch” (automated) decontamination technologies include aerosol and vaporized hydrogen peroxide, mobile devices that emit continuous ultraviolet (UV-C) light, a pulsed-xenon UV light system, and use of high-intensity narrow-spectrum (405 nm) light. These “no-touch” technologies have been shown to reduce bacterial contamination of surfaces. A micro-condensation hydrogen peroxide system has been associated in multiple studies with reductions in healthcare-associated colonization or infection, while there is more limited evidence of infection reduction by the pulsed-xenon system. A recently completed prospective, randomized controlled trial of continuous UV-C light should help determine the extent to which this technology can reduce healthcare-associated colonization and infections. In conclusion, continued efforts to improve traditional manual disinfection of surfaces are needed. In addition, Environmental Services departments should consider the use of newer disinfectants and no-touch decontamination technologies to improve disinfection of surfaces in healthcare.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found
              Is Open Access

              Indoor air humidity, air quality, and health - An overview.

              There is a long-standing dispute about indoor air humidity and perceived indoor air quality (IAQ) and associated health effects. Complaints about sensory irritation in eyes and upper airways are generally among top-two symptoms together with the perception "dry air" in office environments. This calls for an integrated analysis of indoor air humidity and eye and airway health effects. This overview has reviewed the literature about the effects of extended exposure to low humidity on perceived IAQ, sensory irritation symptoms in eyes and airways, work performance, sleep quality, virus survival, and voice disruption. Elevation of the indoor air humidity may positively impact perceived IAQ, eye symptomatology, and possibly work performance in the office environment; however, mice inhalation studies do not show exacerbation of sensory irritation in the airways by low humidity. Elevated humidified indoor air appears to reduce nasal symptoms in patients suffering from obstructive apnea syndrome, while no clear improvement on voice production has been identified, except for those with vocal fatigue. Both low and high RH, and perhaps even better absolute humidity (water vapor), favors transmission and survival of influenza virus in many studies, but the relationship between temperature, humidity, and the virus and aerosol dynamics is complex, which in the end depends on the individual virus type and its physical/chemical properties. Dry and humid air perception continues to be reported in offices and in residential areas, despite the IAQ parameter "dry air" (or "wet/humid air") is semantically misleading, because a sensory organ for humidity is non-existing in humans. This IAQ parameter appears to reflect different perceptions among other odor, dustiness, and possibly exacerbated by desiccation effect of low air humidity. It is salient to distinguish between indoor air humidity (relative or absolute) near the breathing and ocular zone and phenomena caused by moisture-damage of the building construction and emissions therefrom. Further, residential versus public environments should be considered as separate entities with different characteristics and demands of humidity. Research is needed about particle, bacteria and virus dynamics indoors for improvement of quality of life and with more focus on the impact of absolute humidity. "Dry (or wet) air" should be redefined to become a meaningful IAQ descriptor.
                Bookmark

                Author and article information

                Contributors
                Role: ConceptualizationRole: Data curationRole: InvestigationRole: Methodology
                Role: ConceptualizationRole: Data curationRole: InvestigationRole: MethodologyRole: Validation
                Role: Formal analysisRole: Investigation
                Role: ConceptualizationRole: Data curation
                Role: InvestigationRole: MethodologyRole: Visualization
                Role: ConceptualizationRole: Writing – review & editing
                Role: ConceptualizationRole: Data curationRole: Formal analysisRole: Funding acquisitionRole: InvestigationRole: SupervisionRole: ValidationRole: Writing – original draft
                Role: Editor
                Journal
                PLoS One
                PLoS ONE
                plos
                plosone
                PLoS ONE
                Public Library of Science (San Francisco, CA USA )
                1932-6203
                27 December 2019
                2019
                : 14
                : 12
                : e0226952
                Affiliations
                [1 ] Department of Fundamental Nursing, Faculty of Health Sciences, Hokkaido University, Sapporo, Japan
                [2 ] Department of Medical Laboratory Science, Faculty of Health Sciences, Hokkaido University, Sapporo, Japan
                [3 ] Laboratory of Morphology and Image Analysis, Biomedical Research Center, Juntendo University Graduate School of Medicine, Tokyo, Japan
                The University of New Mexico School of Medicine, UNITED STATES
                Author notes

                Competing Interests: The authors have declared that no competing interests exist.

                Author information
                http://orcid.org/0000-0003-3723-3361
                Article
                PONE-D-19-18407
                10.1371/journal.pone.0226952
                6934310
                31881059
                e6d6b082-0aa1-465c-82ee-62dec3d3b04b
                © 2019 Shimoda et al

                This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

                History
                : 30 June 2019
                : 10 December 2019
                Page count
                Figures: 6, Tables: 0, Pages: 17
                Funding
                Funded by: the Japan Science and Technology Agency
                Award Recipient :
                This work was supported by the Japan Science and Technology Agency to HY. The funder had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
                Categories
                Research Article
                Biology and Life Sciences
                Organisms
                Bacteria
                Staphylococcus
                Staphylococcus Aureus
                Biology and Life Sciences
                Microbiology
                Medical Microbiology
                Microbial Pathogens
                Bacterial Pathogens
                Staphylococcus
                Staphylococcus Aureus
                Medicine and Health Sciences
                Pathology and Laboratory Medicine
                Pathogens
                Microbial Pathogens
                Bacterial Pathogens
                Staphylococcus
                Staphylococcus Aureus
                Biology and Life Sciences
                Physiology
                Physiological Parameters
                Body Temperature
                Medicine and Health Sciences
                Physiology
                Physiological Parameters
                Body Temperature
                Medicine and Health Sciences
                Infectious Diseases
                Nosocomial Infections
                Biology and Life Sciences
                Microbiology
                Medical Microbiology
                Microbial Pathogens
                Bacterial Pathogens
                Medicine and Health Sciences
                Pathology and Laboratory Medicine
                Pathogens
                Microbial Pathogens
                Bacterial Pathogens
                Physical Sciences
                Materials Science
                Metallurgy
                Alloys
                Steel
                Stainless Steel
                Earth Sciences
                Atmospheric Science
                Meteorology
                Humidity
                Physical Sciences
                Chemistry
                Chemical Compounds
                Chlorides
                Biology and Life Sciences
                Organisms
                Bacteria
                Enterococcus
                Enterococcus Faecalis
                Biology and Life Sciences
                Microbiology
                Medical Microbiology
                Microbial Pathogens
                Bacterial Pathogens
                Enterococcus
                Enterococcus Faecalis
                Medicine and Health Sciences
                Pathology and Laboratory Medicine
                Pathogens
                Microbial Pathogens
                Bacterial Pathogens
                Enterococcus
                Enterococcus Faecalis
                Custom metadata
                All relevant data are within the manuscript and its Supporting Information files.

                Uncategorized
                Uncategorized

                Comments

                Comment on this article