4
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Standardization of Nucleic Acid Tests: the Approach of the World Health Organization

      , , , ,
      Journal of Clinical Microbiology
      American Society for Microbiology

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          ABSTRACT

          The first World Health Organization (WHO) international standards (ISs) for nucleic acid amplification techniques were established two decades ago, with the initial focus on blood screening for three major viral targets, i.e., hepatitis C virus, hepatitis B virus, and human immunodeficiency virus 1. These reference materials have subsequently found utility in the diagnosis and monitoring of a wide range of infectious diseases in clinical microbiology laboratories worldwide. WHO collaborating centers develop ISs and coordinate international studies for their evaluation. The WHO Expert Committee on Biological Standardization is responsible for the endorsement of new standardization projects and the establishment of new and replacement ISs. Potencies of ISs are defined in international units (IU); the reporting in IU for assays calibrated with an IS (or secondary standards traceable to the IS) facilitates comparability of results for different assays and determination of assay parameters such as analytical sensitivities.

          Related collections

          Most cited references37

          • Record: found
          • Abstract: found
          • Article: not found

          The Third International Consensus Guidelines on the Management of Cytomegalovirus in Solid-organ Transplantation.

          Despite recent advances, cytomegalovirus (CMV) infections remain one of the most common complications affecting solid organ transplant recipients, conveying higher risks of complications, graft loss, morbidity, and mortality. Research in the field and development of prior consensus guidelines supported by The Transplantation Society has allowed a more standardized approach to CMV management. An international multidisciplinary panel of experts was convened to expand and revise evidence and expert opinion-based consensus guidelines on CMV management including prevention, treatment, diagnostics, immunology, drug resistance, and pediatric issues. Highlights include advances in molecular and immunologic diagnostics, improved understanding of diagnostic thresholds, optimized methods of prevention, advances in the use of novel antiviral therapies and certain immunosuppressive agents, and more savvy approaches to treatment resistant/refractory disease. The following report summarizes the updated recommendations.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            Establishment of the 1st World Health Organization International Standard for Plasmodium falciparum DNA for nucleic acid amplification technique (NAT)-based assays

            Background In order to harmonize results for the detection and quantification of Plasmodium falciparum DNA by nucleic acid amplification technique (NAT)-based assays, a World Health Organization (WHO) collaborative study was performed, evaluating a series of candidate standard preparations. Methods Fourteen laboratories from 10 different countries participated in the collaborative study. Four candidate preparations based upon blood samples parasitaemic for P. falciparum were evaluated in the study. Sample AA was lyophilized, whilst samples BB, CC and DD were liquid/frozen preparations. The candidate standards were tested by each laboratory at a range of dilutions in four independent assays, using both qualitative and quantitative NAT-based assays. The results were collated and analysed statistically. Results Twenty sets of data were returned from the participating laboratories and used to determine the mean P. falciparum DNA content for each sample. The mean log10 "equivalents"/ml were 8.51 for sample AA, 8.45 for sample BB, 8.35 for sample CC, and 5.51 for sample DD. The freeze-dried preparation AA, was examined by accelerated thermal degradation studies and found to be highly stable. Conclusion On the basis of the collaborative study, the freeze-dried material, AA (NIBSC code No. 04/176) was established as the 1st WHO International Standard for P. falciparum DNA NAT-based assays and has been assigned a potency of 109 International Units (IU) per ml. Each vial contains 5 × 108 IU, equivalent to 0.5 ml of material after reconstitution.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found
              Is Open Access

              A collaborative study to establish the 1st WHO International Standard for human cytomegalovirus for nucleic acid amplification technology

              Variability in the performance of nucleic acid amplification technology (NAT)-based assays presents a significant problem in the diagnosis and management of human cytomegalovirus (HCMV) infections. Here we describe a collaborative study to evaluate the suitability of candidate reference materials to harmonize HCMV viral load measurements in a wide range of NAT assays. Candidate materials comprised lyophilized Merlin virus, liquid Merlin virus, liquid AD169 virus, and purified HCMV Merlin DNA cloned into a bacterial artificial chromosome. Variability in the laboratory mean HCMV concentrations determined for virus samples across the different assays was 2 log10. Variability for the purified DNA sample was higher (>3 log10). The agreement between laboratories was markedly improved when the potencies of the liquid virus samples were expressed relative to the lyophilized virus candidate. In contrast, the agreement between laboratories for the purified DNA sample was not improved. Results indicated the suitability of the lyophilized Merlin virus preparation as the 1st WHO International Standard for HCMV for NAT. It was established in October 2010, with an assigned potency of 5 × 10(6) International Units (IU) (NIBSC code 09/162). It is intended to be used to calibrate secondary references, used in HCMV NAT assays, in IU.
                Bookmark

                Author and article information

                Journal
                Journal of Clinical Microbiology
                J Clin Microbiol
                American Society for Microbiology
                0095-1137
                1098-660X
                January 2019
                January 02 2019
                September 26 2018
                : 57
                : 1
                Article
                10.1128/JCM.01056-18
                6322456
                30257900
                e5b27f88-4e3c-4700-9da9-047318e1a6cc
                © 2018
                History

                Comments

                Comment on this article