21
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Voltage-Sensitive Fluorescence of Indocyanine Green in the Heart

      research-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          So far, the optical mapping of cardiac electrical signals using voltage-sensitive fluorescent dyes has only been performed in experimental studies because these dyes are not yet approved for clinical use. It was recently reported that the well-known and widely used fluorescent dye indocyanine green (ICG), which has FDA approval, exhibits voltage sensitivity in various tissues, thus raising hopes that electrical activity could be optically mapped in the clinic. The aim of this study was to explore the possibility of using ICG to monitor cardiac electrical activity. Optical mapping experiments were performed on Langendorff rabbit hearts stained with ICG and perfused with electromechanical uncouplers. The residual contraction force and electrical action potentials were recorded simultaneously. Our research confirms that ICG is a voltage-sensitive dye with a dual-component (fast and slow) response to membrane potential changes. The fast component of the optical signal (OS) can have opposite polarities in different parts of the fluorescence spectrum. In contrast, the polarity of the slow component remains the same throughout the entire spectrum. Separating the OS into these components revealed two different voltage-sensitivity mechanisms for ICG. The fast component of the OS appears to be electrochromic in nature, whereas the slow component may arise from the redistribution of the dye molecules within or around the membrane. Both components quite accurately track the time of electrical signal propagation, but only the fast component is suitable for estimating the shape and duration of action potentials. Because ICG has voltage-sensitive properties in the entire heart, we suggest that it can be used to monitor cardiac electrical behavior in the clinic.

          Related collections

          Author and article information

          Contributors
          Journal
          Biophys J
          Biophys. J
          Biophysical Journal
          The Biophysical Society
          0006-3495
          1542-0086
          02 February 2016
          02 February 2016
          : 110
          : 3
          : 723-732
          Affiliations
          [1 ]Lithuanian University of Health Sciences, Kaunas, Lithuania
          Author notes
          []Corresponding author regina.macianskiene@ 123456lsmuni.lt
          Article
          PMC4744163 PMC4744163 4744163 S0006-3495(15)04764-5
          10.1016/j.bpj.2015.12.021
          4744163
          26840736
          d98baab8-9ecb-47fe-8842-07222edd701e
          © 2016 by the Biophysical Society.
          History
          : 20 July 2015
          : 16 December 2015
          Categories
          Systems Biophysics

          Comments

          Comment on this article