7
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Lab-on-a-chip technology: impacting non-invasive prenatal diagnostics (NIPD) through miniaturisation

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references78

          • Record: found
          • Abstract: found
          • Article: not found

          Continuous particle separation through deterministic lateral displacement.

          We report on a microfluidic particle-separation device that makes use of the asymmetric bifurcation of laminar flow around obstacles. A particle chooses its path deterministically on the basis of its size. All particles of a given size follow equivalent migration paths, leading to high resolution. The microspheres of 0.8, 0.9, and 1.0 micrometers that were used to characterize the device were sorted in 40 seconds with a resolution of approximately 10 nanometers, which was better than the time and resolution of conventional flow techniques. Bacterial artificial chromosomes could be separated in 10 minutes with a resolution of approximately 12%.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Noninvasive diagnosis of fetal aneuploidy by shotgun sequencing DNA from maternal blood.

            We directly sequenced cell-free DNA with high-throughput shotgun sequencing technology from plasma of pregnant women, obtaining, on average, 5 million sequence tags per patient sample. This enabled us to measure the over- and underrepresentation of chromosomes from an aneuploid fetus. The sequencing approach is polymorphism-independent and therefore universally applicable for the noninvasive detection of fetal aneuploidy. Using this method, we successfully identified all nine cases of trisomy 21 (Down syndrome), two cases of trisomy 18 (Edward syndrome), and one case of trisomy 13 (Patau syndrome) in a cohort of 18 normal and aneuploid pregnancies; trisomy was detected at gestational ages as early as the 14th week. Direct sequencing also allowed us to study the characteristics of cell-free plasma DNA, and we found evidence that this DNA is enriched for sequences from nucleosomes.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Genome-wide fetal aneuploidy detection by maternal plasma DNA sequencing.

              To prospectively determine the diagnostic accuracy of massively parallel sequencing to detect whole chromosome fetal aneuploidy from maternal plasma. Blood samples were collected in a prospective, blinded study from 2,882 women undergoing prenatal diagnostic procedures at 60 U.S. sites. An independent biostatistician selected all singleton pregnancies with any abnormal karyotype and a balanced number of randomly selected pregnancies with euploid karyotypes. Chromosome classifications were made for each sample by massively parallel sequencing and compared with fetal karyotype. Within an analysis cohort of 532 samples, the following were classified correctly: 89 of 89 trisomy 21 cases (sensitivity 100%, 95% [confidence interval] CI 95.9-100), 35 of 36 trisomy 18 cases (sensitivity 97.2%, 95% CI 85.5-99.9), 11 of 14 trisomy 13 cases (sensitivity 78.6%, 95% CI 49.2-95.3), [corrected] 232 of 233 females (sensitivity 99.6%, 95% CI 97.6 to more than 99.9), 184 of 184 males (sensitivity 100%, 95% CI 98.0-100), and 15 of 16 monosomy X cases (sensitivity 93.8%, 95% CI 69.8-99.8). There were no false-positive results for autosomal aneuploidies (100% specificity, 95% CI more than 98.5 to 100). In addition, fetuses with mosaicism for trisomy 21 (3/3), trisomy 18 (1/1), and monosomy X (2/7), three cases of translocation trisomy, two cases of other autosomal trisomies (20 and 16), and other sex chromosome aneuploidies (XXX, XXY, and XYY) were classified correctly. This prospective study demonstrates the efficacy of massively parallel sequencing of maternal plasma DNA to detect fetal aneuploidy for multiple chromosomes across the genome. The high sensitivity and specificity for the detection of trisomies 21, 18, 13, and monosomy X suggest that massively parallel sequencing can be incorporated into existing aneuploidy screening algorithms to reduce unnecessary invasive procedures. ClinicalTrials.gov, www.clinicaltrials.gov, NCT01122524. II.
                Bookmark

                Author and article information

                Journal
                LCAHAM
                Lab on a Chip
                Lab Chip
                Royal Society of Chemistry (RSC)
                1473-0197
                1473-0189
                2014
                2014
                : 14
                : 5
                : 841
                Article
                10.1039/c3lc50980j
                d74acd1a-a70d-4076-bbce-2d27345c0d2d
                © 2014
                History

                Comments

                Comment on this article