1
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Development of an enzyme immunoassay using recombinant expressed antigen to detect hepatitis delta virus antibodies.

      1 ,
      Journal of clinical microbiology
      American Society for Microbiology

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Two generic enzyme immunoassays (EIAs) were developed for detection of anti-hepatitis delta virus antibodies (anti-HD) and compared with a commercially available radioimmunoassay. Both generic assays were configured as blocking assays and used hepatitis delta antigen (HDAg) derived from infected chimpanzee liver (EIA-1) or from Escherichia coli transformed with a plasmid containing an insert from within an open reading frame encoding HDAg (EIA-2). Absolute sensitivity was ascertained by endpoint titration, which demonstrated essentially identical endpoints for EIA-1 and EIA-2. The absolute sensitivities of the EIAs were approximately four times greater than that of the radioimmunoassay. Specificity and sensitivity were ascertained by testing a panel of 176 serum specimens by each assay. The specimens were selected to represent a panel composed of sera from individuals with or without markers of viral hepatitis as follows: (i) serologically confirmed by exclusion as posttransfusion non-A, non-B hepatitis; (ii) acute or chronic hepatitis B virus infection, positive for hepatitis B surface antigen; (iii) resolved hepatitis B virus infection, positive for anti-hepatitis B surface antigen; (iv) acute hepatitis A virus infection, positive for anti-hepatitis A virus immunoglobulin M; and (v) normal human sera. All three assays for anti-HD gave similar specificity and sensitivity values. In conclusion, the recombinant expressed HDAg can replace antigen derived from infected liver tissue as a diagnostic reagent used to configure an EIA for detection of anti-HD. Furthermore, the results suggest that the expressed antigen contains the important immunodominant epitope(s).

          Related collections

          Author and article information

          Journal
          J Clin Microbiol
          Journal of clinical microbiology
          American Society for Microbiology
          0095-1137
          0095-1137
          Oct 1989
          : 27
          : 10
          Affiliations
          [1 ] Fundacion Gaspar de Portola, Barcelona, Spain.
          Article
          10.1128/jcm.27.10.2222-2225.1989
          266998
          2685022
          d09a0028-d7b0-4b94-86f0-717ed386015b
          History

          Comments

          Comment on this article