20
views
0
recommends
+1 Recommend
1 collections
    0
    shares

      International Journal of Nanomedicine (submit here)

      This international, peer-reviewed Open Access journal by Dove Medical Press focuses on the application of nanotechnology in diagnostics, therapeutics, and drug delivery systems throughout the biomedical field. Sign up for email alerts here.

      105,621 Monthly downloads/views I 7.033 Impact Factor I 10.9 CiteScore I 1.22 Source Normalized Impact per Paper (SNIP) I 1.032 Scimago Journal & Country Rank (SJR)

      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      In vivo evaluation of an antibacterial coating containing halogenated furanone compound-loaded poly(l-lactic acid) nanoparticles on microarc-oxidized titanium implants

      research-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To prevent peri-implant infection, a new antibacterial coating containing a halogenated furanone compound, ( Z-)-4-bromo-5-(bromomethylene)-2(5 H)-furanone-loaded poly( l-lactic acid) nanoparticles, has been fabricated. The current study was designed to evaluate the preventive effect of the antibacterial coating under a simulated environment of peri-implant infection in vivo. Microarc-oxidized titanium implants treated with minocycline hydrochloride ointment were used as positive control group, and microarc-oxidized titanium implants without any treatment were used as blank control group. Three kinds of implants were implanted in dogs’ mandibles, and the peri-implant infection was simulated by silk ligation and feeding high sugar diet. After 2-month implantation, the results showed that no significant differences were detected between the experimental and positive control groups ( P>0.05), but the data of clinical measurements of the blank control group were significantly higher than those of the other two groups ( P<0.05), and the bone–implant contact rate and ultimate interfacial strength were significantly lower than those of the other two groups ( P<0.05). Scanning electron microscope observation and histological examination showed that more new bone was formed on the surface of the experimental and positive control groups. It can be concluded that the antibacterial coating fabricated on implants has remarkable preventive effect on peri-implant infection at the early stage.

          Most cited references33

          • Record: found
          • Abstract: found
          • Article: not found

          Antibacterial coatings on titanium implants.

          Titanium and titanium alloys are key biomedical materials because of their good biocompatibility and mechanical properties. Nevertheless, infection on and around titanium implants still remains a problem which is usually difficult to treat and may lead to eventual implant removal. As a result, preventive measures are necessary to mitigate implant-frelated infection. One important strategy is to render the implant surface antibacterial by impeding the formation of a biofilm. A number of approaches have been proposed for this purpose and they are reviewed in this article. (c) 2009 Wiley Periodicals, Inc.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Antibacterial nano-structured titania coating incorporated with silver nanoparticles.

            Titanium (Ti) implants are widely used clinically but post-operation infection remains one of the most common and serious complications. A surface boasting long-term antibacterial ability is highly desirable in order to prevent implant associated infection. In this study, titania nanotubes (TiO(2)-NTs) incorporated with silver (Ag) nanoparticles are fabricated on Ti implants to achieve this purpose. The Ag nanoparticles adhere tightly to the wall of the TiO(2)-NTs prepared by immersion in a silver nitrate solution followed by ultraviolet light radiation. The amount of Ag introduced to the NTs can be varied by changing processing parameters such as the AgNO(3) concentration and immersion time. The TiO(2)-NTs loaded with Ag nanoparticles (NT-Ag) can kill all the planktonic bacteria in the suspension during the first several days, and the ability of the NT-Ag to prevent bacterial adhesion is maintained without obvious decline for 30 days, which are normally long enough to prevent post-operation infection in the early and intermediate stages and perhaps even late infection around the implant. Although the NT-Ag structure shows some cytotoxicity, it can be reduced by controlling the Ag release rate. The NT-Ag materials are also expected to possess satisfactory osteoconductivity in addition to the good biological performance expected of TiO(2)-NTs. This controllable NT-Ag structure which provides relatively long-term antibacterial ability and good tissue integration has promising applications in orthopedics, dentistry, and other biomedical devices. Copyright © 2011 Elsevier Ltd. All rights reserved.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Antibacterial activity and increased bone marrow stem cell functions of Zn-incorporated TiO2 coatings on titanium.

              In this work, zinc was incorporated into TiO2 coatings on titanium by plasma electrolytic oxidation to obtain the implant with good bacterial inhibition ability and bone-formability. The porous and nanostructured Zn-incorporated TiO2 coatings are built up from pores smaller than 5 μm and grains 20-100 nm in size, in which the element Zn exists as ZnO. The results obtained from the antibacterial studies suggest that the Zn-incorporated TiO2 coatings can greatly inhibit the growth of both Staphylococcus aureus and Escherichia coli, and the ability to inhibit bacteria can be improved by increasing the Zn content in the coatings. Moreover, the in vitro cytocompatibility evaluation demonstrates that the adhesion, proliferation and differentiation of rat bone marrow stem cells (bMSC) on Zn-incorporated coatings are significantly enhanced compared with Zn-free coating and commercially pure Ti plate, and no cytotoxicity appeared on any of the Zn-incorporated TiO2 coatings. Moreover, bMSC express higher level of alkaline phosphatase activity on Zn-incorporated TiO2 coatings and are induced to differentiate into osteoblast cells. The better antibacterial activity, cytocompatibility and the capability to promote bMSC osteogenic differentiation of Zn-incorporated TiO2 coatings may be attributed to the fact that Zn ions can be slowly and constantly released from the coatings. In conclusion, innovative Zn-incorporated TiO2 coatings on titanium with excellent antibacterial activity and biocompatibility are promising candidates for orthopedic and dental implants. Copyright © 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
                Bookmark

                Author and article information

                Journal
                Int J Nanomedicine
                Int J Nanomedicine
                International Journal of Nanomedicine
                International Journal of Nanomedicine
                Dove Medical Press
                1176-9114
                1178-2013
                2016
                30 March 2016
                : 11
                : 1337-1347
                Affiliations
                [1 ]Department of Prosthodontics, State Key Laboratory of Military Stomatology, School of Stomatology, Fourth Military Medical University, Xi’an, People’s Republic of China
                [2 ]Department of Stomatology, Bayi Hospital, Nanjing University of Chinese Medicine, Nanjing, People’s Republic of China
                [3 ]Department of Prosthodontics, Shaanxi Key Laboratory of Stomatology, Xi’an, People’s Republic of China
                [4 ]Institute of Neuroscience, School of Basical Medical Science, Fourth Military Medical University, Xi’an, People’s Republic of China
                Author notes
                Correspondence: Jiang Wu, Department of Prosthodontics, State Key Laboratory of Military Stomatology, School of Stomatology, Fourth Military Medical University, No 145, West Changle Road, Xi’an, Shaanxi 710032, People’s Republic of China, Tel/fax +86 29 8477 6469, Email wujiang@ 123456fmmu.edu.cn
                [*]

                These authors contributed equally to this work

                Article
                ijn-11-1337
                10.2147/IJN.S100763
                4821396
                27099494
                bf647a92-73f1-499a-81fd-94ff449645da
                © 2016 Cheng et al. This work is published and licensed by Dove Medical Press Limited

                The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License ( http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.

                History
                Categories
                Original Research

                Molecular medicine
                antibacterial coating,halogenated furanone,microarc-oxidized,nanoparticles,in vivo

                Comments

                Comment on this article