      Evaluation of Five Decontamination Methods for Filtering Facepiece Respirators

      research-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Concerns have been raised regarding the availability of National Institute for Occupational Safety and Health (NIOSH)-certified N95 filtering facepiece respirators (FFRs) during an influenza pandemic. One possible strategy to mitigate a respirator shortage is to reuse FFRs following a biological decontamination process to render infectious material on the FFR inactive. However, little data exist on the effects of decontamination methods on respirator integrity and performance. This study evaluated five decontamination methods [ultraviolet germicidal irradiation (UVGI), ethylene oxide, vaporized hydrogen peroxide (VHP), microwave oven irradiation, and bleach] using nine models of NIOSH-certified respirators (three models each of N95 FFRs, surgical N95 respirators, and P100 FFRs) to determine which methods should be considered for future research studies. Following treatment by each decontamination method, the FFRs were evaluated for changes in physical appearance, odor, and laboratory performance (filter aerosol penetration and filter airflow resistance). Additional experiments (dry heat laboratory oven exposures, off-gassing, and FFR hydrophobicity) were subsequently conducted to better understand material properties and possible health risks to the respirator user following decontamination. However, this study did not assess the efficiency of the decontamination methods to inactivate viable microorganisms. Microwave oven irradiation melted samples from two FFR models. The remainder of the FFR samples that had been decontaminated had expected levels of filter aerosol penetration and filter airflow resistance. The scent of bleach remained noticeable following overnight drying and low levels of chlorine gas were found to off-gas from bleach-decontaminated FFRs when rehydrated with deionized water. UVGI, ethylene oxide (EtO), and VHP were found to be the most promising decontamination methods; however, concerns remain about the throughput capabilities for EtO and VHP. Further research is needed before any specific decontamination methods can be recommended.

          Related collections

          Most cited references25

          • Record: found
          • Abstract: found
          • Article: not found

          Uses of inorganic hypochlorite (bleach) in health-care facilities.

          Hypochlorite has been used as a disinfectant for more than 100 years. It has many of the properties of an ideal disinfectant, including a broad antimicrobial activity, rapid bactericidal action, reasonable persistence in treated potable water, ease of use, solubility in water, relative stability, relative nontoxicity at use concentrations, no poisonous residuals, no color, no staining, and low cost. The active species is undissociated hypochlorous acid (HOCl). Hypochlorites are lethal to most microbes, although viruses and vegetative bacteria are more susceptible than endospore-forming bacteria, fungi, and protozoa. Activity is reduced by the presence of heavy metal ions, a biofilm, organic material, low temperature, low pH, or UV radiation. Clinical uses in health-care facilities include hyperchlorination of potable water to prevent Legionella colonization, chlorination of water distribution systems used in hemodialysis centers, cleaning of environmental surfaces, disinfection of laundry, local use to decontaminate blood spills, disinfection of equipment, decontamination of medical waste prior to disposal, and dental therapy. Despite the increasing availability of other disinfectants, hypochlorites continue to find wide use in hospitals.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Asthma, chronic bronchitis, and exposure to irritant agents in occupational domestic cleaning: a nested case-control study.

            Women employed in domestic cleaning are at increased risk for symptoms of obstructive lung disease, but the agents responsible are unknown. To investigate common tasks and products in occupational domestic cleaning in relation to respiratory morbidity. Case-control study in domestic cleaning women nested within a large population based survey of women aged 30-65 years; 160 domestic cleaning women with asthma symptoms, chronic bronchitis symptoms, or both and 386 without a history of respiratory symptoms were identified. Detailed exposures were evaluated for 40 cases who reported still having symptoms at the recruitment interview, and 155 controls who reported not having symptoms. All tasks performed and products used when cleaning houses were determined in a face-to-face interview. Lung function, methacholine challenge, and serum IgE testing were performed. Personal exposure measurements of airborne chlorine and ammonia were performed in a subsample. Associations between asthma, chronic bronchitis, and cleaning exposures were evaluated using multiple logistic regression analysis. Airborne chlorine (median level 0-0.4 ppm) and ammonia (0.6-6.4 ppm) were detectable during occupational domestic cleaning activities. Cases used bleach more frequently than controls; adjusted odds ratio (OR) for intermediate exposure was 3.3 (95% CI 0.9 to 11) and for high exposure 4.9 (1.5 to 15). Other independent associations included accidental inhalation of vapours and gases from cleaning agents and washing dishes. These associations were more pronounced for cases with asthma symptoms than for those with symptoms of chronic bronchitis, but were not related to sensitisation to common allergens. Asthma symptoms in domestic cleaning women are associated with exposure to bleach and possibly other irritant agents. The public health impact of the use of irritant cleaning products could be widespread since the use of these products is common both in the workplace and at home.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Effect of Decontamination on the Filtration Efficiency of Two Filtering Facepiece Respirator Models

                Bookmark

                Author and article information

                Journal
                Ann Occup Hyg
                Ann Occup Hyg
                annhyg
                annhyg
                Annals of Occupational Hygiene
                Oxford University Press
                0003-4878
                1475-3162
                November 2009
                4 October 2009
                : 53
                : 8
                : 815-827
                Affiliations
                [1 ]National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, 626 Cochrans Mill Road, Pittsburgh, PA 15236, USA
                [2 ]EG&G Technical Services, Inc., 626 Cochrans Mill Road, PO Box 18070, Pittsburgh, PA 15236, USA
                Author notes
                [* ]Author to whom correspondence should be addressed. Tel: +412-386-4001; fax: +412-386-6864; e-mail: rshaffer@ 123456cdc.gov
                Article
                10.1093/annhyg/mep070
                2781738
                19805391
                b7d80be4-b0cb-4c3f-8126-d3478e407570
                © The Author 2009. Published by Oxford University Press on behalf of the British Occupational Hygiene Society

                This article is made available via the PMC Open Access Subset for unrestricted re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the COVID-19 pandemic or until permissions are revoked in writing. Upon expiration of these permissions, PMC is granted a perpetual license to make this article available via PMC and Europe PMC, consistent with existing copyright protections.

                History
                : 27 May 2009
                : 2 September 2009
                Categories
                Original Articles

                Occupational & Environmental medicine
                decontamination,filtering facepiece respirator,healthcare workers,n95 respirator,pandemic influenza,respirator reuse

                Comments