      Assessment of nosocomial bacterial contamination in dental unit waterlines: Impact of flushing

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose

          This study evaluated the extent of bacterial contamination in water from dental unit waterlines (DUWLs).

          Methodology

          Water samples were collected (before flushing, 1 min post-flushing, and 3 min post-flushing) from 24 clinics (Group A: no disinfection, Group B: citric acid disinfectant) of a Government Dental College. Bacterial counts, identification, antibiotic sensitivity tests, determination of endotoxin levels, and scanning electron microscopy (to confirm the presence of biofilm) were performed.

          Results

          The most common opportunistic bacteria were P. aeruginosa (95%), S. aureus (58%), S. auricularis (49%), P. fluorescens (44%), and A. baumannii (20%). Approximately 50% of the bacterial isolates were resistant to two or more antibiotics. Flushing for 3 min did not reduce the contamination of water from Group A clinics which exceeded the recommendation of ≤500 CFU/ml. No bacterial growth was seen in Group B samples. Endotoxin levels were >5.00 endotoxin units (EU)/ml in Group A and ranged from 1.33 to 5.00 EU/ml in Group B clinics. Scanning electron microscopy images showed bacterial biofilms on the surfaces of the tubes.

          Conclusions

          DUWL contamination is a serious issue in dentistry, and the microbiological quality of the water must be monitored regularly. Further studies on endotoxin exposure and prevention are therefore necessary.

          Related collections

          Most cited references26

          • Record: found
          • Abstract: found
          • Article: not found

          Guidelines for infection control in dental health-care settings--2003.

          This report consolidates previous recommendations and adds new ones for infection control in dental settings. Recommendations are provided regarding 1) educating and protecting dental health-care personnel; 2) preventing transmission of bloodborne pathogens; 3) hand hygiene; 4) personal protective equipment; 5) contact dermatitis and latex hypersensitivity; 6) sterilization and disinfection of patient-care items; 7) environmental infection control; 8) dental unit waterlines, biofilm, and water quality; and 9) special considerations (e.g., dental handpieces and other devices, radiology, parenteral medications, oral surgical procedures, and dental laboratories). These recommendations were developed in collaboration with and after review by authorities on infection control from CDC and other public agencies, academia, and private and professional organizations.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Biofilm problems in dental unit water systems and its practical control.

            Dental chair units (DCUs) contain integrated systems that provide the instruments and services for a wide range of dental procedures. DCUs use water to cool and irrigate DCU-supplied instruments and tooth surfaces during dental treatment. Water is supplied to these instruments by a network of interconnected narrow-bore (2-3 mm) plastic tubes called dental unit waterlines (DUWLs). Many studies over the last 40 years demonstrated that DUWL output water is often contaminated with high densities of micro-organisms, predominantly Gram-negative aerobic heterotropic environmental bacteria, including Legionella and Pseudomonas species. Untreated DUWLs host biofilms that permit micro-organisms to multiply and disperse through the water network and which are aerosolized by DCU instrument use, thus exposing patients and staff to these micro-organisms, to fragments of biofilm and bacterial endotoxins. This review concentrates on how practical developments and innovations in specific areas can contribute to effective DUWL biofilm control. These include the use of effective DUWL treatment agents, improvements to DCU supply water quality, DCU design changes, development of automated DUWL treatment procedures that are effective at controlling biofilm in the long-term and require minimal human intervention, are safe for patients and staff, and which do not cause deterioration of DCU components following prolonged use.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Effects of Hydrogen Peroxide on Dental Unit Biofilms and Treatment Water Contamination

              Objectives: To study effects of various concentrations of hydrogen peroxide on mature waterline biofilms and in controlling planktonic (free-floating) organisms in simulated dental treatment water systems; and to study in vitro the effects of 2%, 3%, and 7% hydrogen peroxide on the removal of mature biofilms and inorganic compounds in dental waterlines. Methods: Four units of an automated dental unit water system simulation device was used for 12 weeks. All units were initially cleaned to control biofilms and inorganic deposits. H2O2 at concentrations of 1%, 2%, 3% was used weekly for periodic cleaning in three treatment group units (units 1, 2 & 3), with 0.05%, 0.15% and 0.25% H2O2 in municipal water used as irrigant respectively. The control unit (unit 4) did not have weekly cleanings and used municipal water as irrigant. Laser Scanning Confocal Microscopy and Scanning Electron Microscopy were used to study deposits on lines, and weekly heterotrophic plate counts done to study effluent water contamination. A 24 hour in vitro challenge test with 7%, 3% and 2% H2O2 on mature biofilms was conducted using harvested waterlines to study biofilm and inorganic deposit removal. Results: Heterotrophic plate counts of effluent water showed that the control unit reached contamination levels in excess of 400,000 CFU/mL while all treatment units showed contamination levels <500 CFU/mL through most of the 12 weeks. All treatment units showed varying levels of biofilm and inorganic deposit control in this short 12 week study. The in vitro challenge test showed although there was biofilm control, there was no eradication even when 7% H2O2 was used for 24 hours. Conclusions: 2% H2O2 used as a periodic cleaner, and diluted to 0.05% in municipal water for irrigation was beneficial in controlling biofilm and planktonic contamination in dental unit water systems. However, to remove well established biofilms, it may take more than 2 months when initial and multiple periodic cleanings are performed using H2O2.
                Bookmark

                Author and article information

                Contributors
                Journal
                Saudi Dent J
                Saudi Dent J
                The Saudi Dental Journal
                Elsevier
                1013-9052
                1658-3558
                19 July 2019
                February 2020
                19 July 2019
                : 32
                : 2
                : 68-73
                Affiliations
                [a ]Department of Botany and Microbiology, College of Science, King Saud University, Riyadh, Saudi Arabia
                [b ]Dental College, King Saud University, Riyadh, Saudi Arabia
                [c ]Prince Sultan Military Medical City, Riyadh, Saudi Arabia
                Author notes
                [* ]Corresponding author at: Box office: 55670, 11544 Riyadh, Saudi Arabia. manalk@ 123456ksu.edu.sa
                Article
                S1013-9052(19)30413-4
                10.1016/j.sdentj.2019.07.003
                7016225
                32071534
                b470e554-8190-4a02-8d8e-49c01d4e152f
                © 2019 The Authors

                This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

                History
                : 4 April 2019
                : 4 July 2019
                : 9 July 2019
                Categories
                Original Article

                bacteria,biofilm,endotoxin,dental unit waterlines,flushing
                bacteria, biofilm, endotoxin, dental unit waterlines, flushing

                Comments

                Comment on this article