      Perception of Sung Speech in Bimodal Cochlear Implant Users

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Combined use of a hearing aid (HA) and cochlear implant (CI) has been shown to improve CI users’ speech and music performance. However, different hearing devices, test stimuli, and listening tasks may interact and obscure bimodal benefits. In this study, speech and music perception were measured in bimodal listeners for CI-only, HA-only, and CI + HA conditions, using the Sung Speech Corpus, a database of monosyllabic words produced at different fundamental frequencies. Sentence recognition was measured using sung speech in which pitch was held constant or varied across words, as well as for spoken speech. Melodic contour identification (MCI) was measured using sung speech in which the words were held constant or varied across notes. Results showed that sentence recognition was poorer with sung speech relative to spoken, with little difference between sung speech with a constant or variable pitch; mean performance was better with CI-only relative to HA-only, and best with CI + HA. MCI performance was better with constant words versus variable words; mean performance was better with HA-only than with CI-only and was best with CI + HA. Relative to CI-only, a strong bimodal benefit was observed for speech and music perception. Relative to the better ear, bimodal benefits remained strong for sentence recognition but were marginal for MCI. While variations in pitch and timbre may negatively affect CI users’ speech and music perception, bimodal listening may partially compensate for these deficits.

          Related collections

          Most cited references27

          • Record: found
          • Abstract: found
          • Article: not found

          Speech recognition in noise as a function of the number of spectral channels: comparison of acoustic hearing and cochlear implants.

          Speech recognition was measured as a function of spectral resolution (number of spectral channels) and speech-to-noise ratio in normal-hearing (NH) and cochlear-implant (CI) listeners. Vowel, consonant, word, and sentence recognition were measured in five normal-hearing listeners, ten listeners with the Nucleus-22 cochlear implant, and nine listeners with the Advanced Bionics Clarion cochlear implant. Recognition was measured as a function of the number of spectral channels (noise bands or electrodes) at signal-to-noise ratios of + 15, + 10, +5, 0 dB, and in quiet. Performance with three different speech processing strategies (SPEAK, CIS, and SAS) was similar across all conditions, and improved as the number of electrodes increased (up to seven or eight) for all conditions. For all noise levels, vowel and consonant recognition with the SPEAK speech processor did not improve with more than seven electrodes, while for normal-hearing listeners, performance continued to increase up to at least 20 channels. Speech recognition on more difficult speech materials (word and sentence recognition) showed a marginally significant increase in Nucleus-22 listeners from seven to ten electrodes. The average implant score on all processing strategies was poorer than scores of NH listeners with similar processing. However, the best CI scores were similar to the normal-hearing scores for that condition (up to seven channels). CI listeners with the highest performance level increased in performance as the number of electrodes increased up to seven, while CI listeners with low levels of speech recognition did not increase in performance as the number of electrodes was increased beyond four. These results quantify the effect of number of spectral channels on speech recognition in noise and demonstrate that most CI subjects are not able to fully utilize the spectral information provided by the number of electrodes used in their implant.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            The multilingual matrix test: Principles, applications, and comparison across languages: A review.

            A review of the development, evaluation, and application of the so-called 'matrix sentence test' for speech intelligibility testing in a multilingual society is provided. The format allows for repeated use with the same patient in her or his native language even if the experimenter does not understand the language.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Noise susceptibility of cochlear implant users: the role of spectral resolution and smearing.

              The latest-generation cochlear implant devices provide many deaf patients with good speech recognition in quiet listening conditions. However, speech recognition deteriorates rapidly as the level of background noise increases. Previous studies have shown that, for cochlear implant users, the absence of fine spectro-temporal cues may contribute to poorer performance in noise, especially when the noise is dynamic (e.g., competing speaker or modulated noise). Here we report on sentence recognition by cochlear implant users and by normal-hearing subjects listening to an acoustic simulation of a cochlear implant, in the presence of steady or square-wave modulated speech-shaped noise. Implant users were tested using their everyday, clinically assigned speech processors. In the acoustic simulation, normal-hearing listeners were tested for different degrees of spectral resolution (16, eight, or four channels) and spectral smearing (carrier filter slopes of -24 or -6 dB/octave). For modulated noise, normal-hearing listeners experienced significant release from masking when the original, unprocessed speech was presented (which preserved the spectro-temporal fine structure), while cochlear implant users experienced no release from masking. As the spectral resolution was reduced, normal-hearing listeners' release from masking gradually diminished. Release from masking was further reduced as the degree of spectral smearing increased. Interestingly, the mean speech recognition thresholds of implant users were very close to those of normal-hearing subjects listening to four-channel spectrally smeared noise-band speech. Also, the best cochlear implant listeners performed like normal-hearing subjects listening to eight- to 16-channel spectrally smeared noise-band speech. These findings suggest that implant users' susceptibility to noise may be caused by the reduced spectral resolution and the high degree of spectral smearing associated with channel interaction. Efforts to improve the effective number of spectral channels as well as reduce channel interactions may improve implant performance in noise, especially for temporally modulated noise.
                Bookmark

                Author and article information

                Journal
                Trends Hear
                Trends Hear
                TIA
                sptia
                Trends in Hearing
                SAGE Publications (Sage CA: Los Angeles, CA )
                2331-2165
                11 November 2016
                Jan-Dec 2016
                : 20
                : 2331216516669329
                Affiliations
                [1 ]University of Southern California, Los Angeles, CA, USA
                [2 ]University of California-Los Angeles, CA, USA
                Author notes
                [*]Joseph D. Crew, Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, Denney Research Center (DRB) 140, Los Angeles, CA 90089, USA. Email: jcrew.research@ 123456gmail.com
                Article
                10.1177_2331216516669329
                10.1177/2331216516669329
                5117252
                27837051
                ae0f333d-a5fe-4945-8e88-4881a4d0977a
                © The Author(s) 2016

                This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 License ( http://www.creativecommons.org/licenses/by-nc/3.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages ( https://us.sagepub.com/en-us/nam/open-access-at-sage).

                History
                : 23 February 2016
                : 22 August 2016
                : 23 August 2016
                Categories
                Original Articles
                Custom metadata
                January-December 2016

                cochlear implants,pitch perception,atypical speech,electro-acoustic stimulation,bimodal perception

                Comments

                Comment on this article