4
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Evaluation of the effects on SpO2 of N95 mask (FFP2) on dental health care providers: a cross-sectional observational study

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Objective

          The purpose of this cross-sectional observational study was to evaluate the effects of SpO2 in a sample of dental health care providers who wear a N95 mask or Filtering Face Piece (FFP2) for four consecutive hours, measured by a pulse oximeter before donning the mask and again after four hours of work and to offer some strategies to minimize discomfort and improve communication with their patients while wearing the mask.

          Materials and methods

          A 17-item questionnaire was sent via Google Drive to various practitioners in Italy and the USA. A sample of 162 questionnaires were returned from dentists, orthodontists, dental hygienists and dental assistants who committed to wearing a FFP2 for 4 consecutive hours during a work day and then measuring the oxygen saturation by way of a pulse oximeter before and after the 4 working hours. The final analysis was performer on 147 viable questionnaires returned. The sample was composed of 62 males and 85 females with an average age of 42.9 ± 12.0 years.

          Results

          For the entire sample population, the baseline saturation was 98.6  ± 1.2 and, after four hours of mask wearing, there was a significant decrease in oxygen saturation to 97.0 ± 2.9 ( p < 0.01). No statistical differences in SpO 2 were found across specialties or across types of procedures performed during the 4 h. Heart rates were not significantly different before and after the 4 h in all categories. The 3 most frequent reported complaints were: fatigue (64%), headache (36%) and external ear pain (31%). The most common additional personal protective equipment (PPE) was a mask shield (78%) and those who wore the mask continuously reported more communication difficulty with patients, compared with those who took the mask off more often, in fact, 64% of the subjects reported that using the mask influenced their communication with their patients. Based on the results of the questionnaire, a list of breathing and vocal folds health strategies was devised and proposed, along with strategies to augment communication with patients.

          Conclusions

          This study highlights a significant decrease in oxygen saturation after only 4 h of work (except for smokers) while wearing a FFP2, and confirms the widespread symptoms of fatigue, headache and pain behind the ears that dental professionals experience. But it also highlighted how mask wearing impaired communication with patients and wearing additional masks and a facial shield may add to those communications difficulties. This aspect and the need for better communication can lead the operators to remove the mask to improve breathing and communication, thus putting themselves at a risk of infection. Of all the aspects explored in this study, the most interesting was indeed the impact on fatigue and communication and the strategies proposed in this article can easily be implemented to reduce headache and fatigue by improving breathing efficiency and by aiding communication while donning a mask by improving voice quality and by using augmentative communication tools.

          Related collections

          Most cited references10

          • Record: found
          • Abstract: found
          • Article: not found

          Pulse oximetry.

          Pulse oximetry is universally used for monitoring patients in the critical care setting. This article updates the review on pulse oximetry that was published in 1999 in Critical Care. A summary of the recently developed multiwavelength pulse oximeters and their ability in detecting dyshemoglobins is provided. The impact of the latest signal processing techniques and reflectance technology on improving the performance of pulse oximeters during motion artifact and low perfusion conditions is critically examined. Finally, data regarding the effect of pulse oximetry on patient outcome are discussed.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Preliminary report on surgical mask induced deoxygenation during major surgery

              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Protective Face Masks: Effect on the Oxygenation and Heart Rate Status of Oral Surgeons during Surgery

              Background: Safety in medical work requires eye protection, such as glasses, and protective facial masks (PFM) during clinical practice to prevent viral respiratory infections. The use of facial masks and other full personal protective equipment increases air flow resistance, facial skin temperature and physical discomfort. The aim of the present study was to measure surgeons’ oxygenation status and discomfort before and after their daily routine activities of oral interventions. Methods: 10 male voluntary dentists, specializing in oral surgery, and 10 male voluntary doctors in dentistry, participating in master’s courses in oral surgery in the Department of Oral Surgery of the University of Chieti, with mean age 29 ± 6 (27–35), were enrolled. This study was undertaken to investigate the effects of wearing a PFM on oxygenation status while the oral surgeons were actively working. Disposable sterile one-way surgical paper masks (Surgical Face Mask, Euronda, Italy) and FFP2 (Surgical Face Mask, Euronda, Italy) were used and the mask position covering the nose did not vary during the procedures. The FFP2 was covered by a surgical mask during surgical treatment. A pulse oximeter was used to measure the blood oximetry saturation during the study. Results: In all 20 surgeons wearing FFP2 covered by surgical masks, a reduction in arterial O2 saturation from around 97.5% before surgery to 94% after surgery was recorded with increase of heart rates. A shortness of breath and light-headedness/headaches were also noted. Conclusions: In conclusion, wearing an FFP2 covered by a surgical mask induces a reduction in circulating O2 concentrations without clinical relevance, while an increase of heart frequency and a sensation of shortness of breath, light-headedness/headaches were recorded.
                Bookmark

                Author and article information

                Contributors
                sabinasaccomanno@hotmail.it
                Journal
                BMC Health Serv Res
                BMC Health Serv Res
                BMC Health Services Research
                BioMed Central (London )
                1472-6963
                24 February 2022
                24 February 2022
                2022
                : 22
                : 248
                Affiliations
                [1 ]GRID grid.158820.6, ISNI 0000 0004 1757 2611, Department of Health, Life and Environmental Science, , University of L’Aquila, Piazza Salvatore Tommasi, ; 67100 L’Aquila, Italy
                [2 ]Academy of Orofacial Myofunctional Therapy (AOMT), 910 Via De La Paz, Ste.106, Pacific Palisades, CA USA
                [3 ]Speech-Language Pathologist, Singing Voice Specialist & Myofunctional Therapist in Culver City, Culver City, CA USA
                [4 ]ENT Department, Rivoli Hospital, ASLTO3, Rivoli, Italy
                Article
                7648
                10.1186/s12913-022-07648-5
                8866552
                35209892
                988e2dea-d6f1-4869-83d6-1a8ed500de75
                © The Author(s) 2022

                Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

                History
                : 2 August 2021
                : 14 February 2022
                Categories
                Research
                Custom metadata
                © The Author(s) 2022

                Health & Social care
                ffp2 mask,n95 mask: hypoxemia,dental care providers,pulse oximetry,pulse oximeter,spo2,communication, covid-19

                Comments

                Comment on this article