36
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Biomechanical Evaluation of a Tooth Restored with High Performance Polymer PEKK Post-Core System: A 3D Finite Element Analysis

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The aim of this study was to evaluate the biomechanical behavior and long-term safety of high performance polymer PEKK as an intraradicular dental post-core material through comparative finite element analysis (FEA) with other conventional post-core materials. A 3D FEA model of a maxillary central incisor was constructed. A cyclic loading force of 50 N was applied at an angle of 45° to the longitudinal axis of the tooth at the palatal surface of the crown. For comparison with traditionally used post-core materials, three materials (gold, fiberglass, and PEKK) were simulated to determine their post-core properties. PEKK, with a lower elastic modulus than root dentin, showed comparably high failure resistance and a more favorable stress distribution than conventional post-core material. However, the PEKK post-core system showed a higher probability of debonding and crown failure under long-term cyclic loading than the metal or fiberglass post-core systems.

          Related collections

          Most cited references36

          • Record: found
          • Abstract: found
          • Article: not found

          Polyetheretherketone as a biomaterial for spinal applications.

          Threaded lumbar interbody spinal fusion devices (TIBFD) made from titanium have been reported to be 90% effective for single-level lumbar interbody fusion, although radiographic determination of fusion has been intensely debated in the literature. Using blinded radiographic, biomechanic, histologic, and statistical measures, we evaluated a radiolucent polyetheretherketone (PEEK)-threaded interbody fusion device packed with autograft or rhBMP-2 on an absorbable collagen sponge in 13 sheep at 6 months. Radiographic fusion, increased spinal level biomechanical stiffness, and histologic fusion were demonstrated for the PEEK cages filled with autograft or rhBMP-2 on a collagen sponge. No device degradation or wear debris was observed. Only mild chronic inflammation consisting of a few macrophages was observed in peri-implant tissues. Based on these results, the polymeric biomaterial PEEK may be a useful biomaterial for interbody fusion cages due to the polymer's increased radiolucency and decreased stiffness.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Resistance to fracture of endodontically treated teeth restored with different post systems.

            Very little is known about the resistance to fracture of endodontically treated teeth restored with newly developed esthetic post systems. Purpose. This in vitro study compared the effect of 1 titanium and 3 esthetic post systems on the fracture resistance and fracture patterns of crowned, endodontically treated teeth. A total of 40 recently extracted human maxillary canines with their crowns removed were endodontically treated. Four groups of 10 specimens were formed. Teeth were restored with titanium, quartz fiber, glass fiber, and zirconia posts and numbered as groups 1, 2, 3, and 4, respectively. All posts were cemented with Single Bond dental adhesive system and dual-polymerizing RelyX ARC adhesive resin cement. All teeth were restored with composite cores, and metal crowns were fabricated and cemented with glass ionomer cement. Each specimen was embedded in acrylic resin and then secured in a universal load-testing machine. A compressive load was applied at a 130-degree angle to the long axis of the tooth until fracture, at a crosshead speed of 1 mm/min. One-way analysis of variance and a Tukey test were used to determine the significance of the failure loads between groups (P .05). Fractures that would allow repair of the tooth were observed in groups 2 and 3, whereas unrestorable, catastrophic fractures were observed in groups 1 and 4 (P<.001). Within the limitations of this study, significantly higher failure loads were recorded for root canal treated teeth restored with quartz fiber posts. Fractures that would allow repeated repair were observed in teeth restored with quartz fiber and glass fiber posts.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Finite element analysis of a glass fibre reinforced composite endodontic post.

              In this work the mechanical response to external applied loads of a new glass fibre reinforced endodontic post is simulated by finite element (FE) analysis of a bidimensional model. The new post has a cylindrical shape with a smooth conical end in order to adequately fit the root cavity, and to avoid edges that could act as undesired stress concentrators. Mechanical data obtained by three-point bending tests on some prototypes fabricated in the laboratory are presented and used in the FE model. Under various loading conditions, the resulting stress component fields are hence compared with those obtained in the case of two commercial endodontic posts (i.e. a cast metal post and a carbon fibre post) and with the response of a natural tooth. The gold cast post-and-core produces the greatest stress concentration at the post-dentin interface. On the other hand, fibre-reinforced composite posts do present quite high stresses in the cervical region due to their flexibility and also to the presence of a less stiff core material. The glass fibre composite shows the lowest peak stresses inside the root because its stiffness is much similar to dentin. Except for the force concentration at the cervical margin, the glass fibre composite post induces a stress field quite similar to that of the natural tooth.
                Bookmark

                Author and article information

                Journal
                Biomed Res Int
                Biomed Res Int
                BMRI
                BioMed Research International
                Hindawi
                2314-6133
                2314-6141
                2017
                12 March 2017
                : 2017
                : 1373127
                Affiliations
                1Department of Prosthodontics, Korea University Guro Hospital, Seoul, Republic of Korea
                2Department of Conservative Dentistry, Korea University Guro Hospital, Seoul, Republic of Korea
                3Department of Prosthodontics, College of Dentistry, Yonsei University, Seoul, Republic of Korea
                4Graduate School of Clinical Dentistry, Korea University, Seoul, Republic of Korea
                Author notes
                *Jeong-Yol Lee: wddc@ 123456korea.ac.kr

                Academic Editor: Andrea Scribante

                Author information
                http://orcid.org/0000-0002-6933-3589
                http://orcid.org/0000-0003-3079-0376
                Article
                10.1155/2017/1373127
                5366183
                28386547
                93f68623-3d8c-4b8b-81a2-fbdc1ab655a1
                Copyright © 2017 Ki-Sun Lee et al.

                This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 11 January 2017
                : 5 March 2017
                Categories
                Research Article

                Comments

                Comment on this article