      Algorithm Variability in the Estimation of Lung Nodule Volume From Phantom CT Scans: Results of the QIBA 3A Public Challenge

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          <div class="section"> <a class="named-anchor" id="S1"> <!-- named anchor --> </a> <h5 class="section-title" id="d2697138e402">Rationale and Objectives:</h5> <p id="P1">Quantifying changes in lung tumor volume is important for diagnosis, therapy planning, and evaluation of response to therapy. The aim of this study was to assess the performance of multiple algorithms on a reference data set. The study was organized by the Quantitative Imaging Biomarker Alliance (QIBA). </p> </div><div class="section"> <a class="named-anchor" id="S2"> <!-- named anchor --> </a> <h5 class="section-title" id="d2697138e407">Materials and Methods:</h5> <p id="P2">The study was organized as a public challenge. Computed tomography scans of synthetic lung tumors in an anthropomorphic phantom were acquired by the Food and Drug Administration. Tumors varied in size, shape, and radiodensity. Participants applied their own semi-automated volume estimation algorithms that either did not allow or allowed post-segmentation correction (type 1 or 2, respectively). Statistical analysis of accuracy (percent bias) and precision (repeatability and reproducibility) was conducted across algorithms, as well as across nodule characteristics, slice thickness, and algorithm type. </p> </div><div class="section"> <a class="named-anchor" id="S3"> <!-- named anchor --> </a> <h5 class="section-title" id="d2697138e412">Results:</h5> <p id="P3">Eighty-four percent of volume measurements of QIBA-compliant tumors were within 15% of the true volume, ranging from 66% to 93% across algorithms, compared to 61% of volume measurements for all tumors (ranging from 37% to 84%). Algorithm type did not affect bias substantially; however, it was an important factor in measurement precision. Algorithm precision was notably better as tumor size increased, worse for irregularly shaped tumors, and on the average better for type 1 algorithms. Over all nodules meeting the QIBA Profile, precision, as measured by the repeatability coefficient, was 9.0% compared to 18.4% overall. </p> </div><div class="section"> <a class="named-anchor" id="S4"> <!-- named anchor --> </a> <h5 class="section-title" id="d2697138e417">Conclusion:</h5> <p id="P4">The results achieved in this study, using a heterogeneous set of measurement algorithms, support QIBA quantitative performance claims in terms of volume measurement repeatability for nodules meeting the QIBA Profile criteria. </p> </div>

          Related collections

          Author and article information

          Journal
          Academic Radiology
          Academic Radiology
          Elsevier BV
          10766332
          August 2016
          August 2016
          : 23
          : 8
          : 940-952
          Article
          10.1016/j.acra.2016.02.018
          6237094
          27215408
          7b207982-6ffe-42e6-9eb7-dd132e3abe66
          © 2016

          https://www.elsevier.com/tdm/userlicense/1.0/

          History

          Comments

          Comment on this article

          scite_
          0
          0
          0
          0
          Smart Citations
          0
          0
          0
          0
          Citing PublicationsSupportingMentioningContrasting
          View Citations

          See how this article has been cited at scite.ai

          scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

          Similar content2,429

          Cited by8