13
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Detection of coronary artery disease by magnetic resonance myocardial perfusion imaging with various contrast medium doses: first European multi-centre experience.

      European Heart Journal
      Analysis of Variance, Contrast Media, administration & dosage, Coronary Artery Disease, diagnosis, Female, Humans, Magnetic Resonance Angiography, methods, Male, Middle Aged, Risk Factors

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Magnetic resonance (MR) first-pass myocardial perfusion imaging during hyperaemia detects coronary artery stenoses in humans with test sensitivity depending on contrast medium (CM)-induced signal change in myocardium. In this prospective multi-centre study, the effect of CM dose on myocardial signal change and on diagnostic performance was evaluated using a stress-only approach. Ninety-four patients with known or suspected coronary artery disease (CAD) were randomised to 0.05,0.10, or 0.15 mmol/kg body weight of an extravascular CM (Gd-DTPA) and X-ray coronary angiography was performed within 30 days prior/after the MR examination. A multi-slice MR technique with identical hardware and software in all centres was used during hyperaemia (adenosine 0.14 mg/kg/min) to monitor myocardial CM wash-in kinetics and data were analysed semi-automatically in a core laboratory. Protocol violations resulted in 80 complete studies with CAD (defined as > or =1 vessel with diameter stenosis > or =50% on quantitative coronary angiography) present in 19/29, 13/24, and 20/27 patients for doses 1, 2, and 3, respectively. In normal myocardium, the upslope increased with CM dose (overall-p<0.0001, ANOVA). For CAD detection the area under the receiver operator characteristics curve for subendocardial data (3 slices with quality score<4 representing 86% of cases) was 0.91+/-0.07 and 0.86+/-0.08 for doses 2 and 3, respectively, and was lower for dose 1 (0.53+/-0.13, p<0.01 and p<0.02 vs. doses 2 and 3, respectively). Corresponding sensitivities/specificities (95% confidence intervals) for pooled doses 2/3 were 93% (77-99%; ns vs. dose 1) and 75% (48-92%;p<0.05 vs. dose 1), respectively. With increasing doses of CM, a higher signal response in the myocardium was achieved and consequently this stress-only protocol, with CM doses of 0.10-0.15 mmol/kg combined with a semi-automatic analysis, yielded a high diagnostic performance for the detection of CAD.

          Related collections

          Author and article information

          Comments

          Comment on this article