2
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      A label-free dual immunosensor for the simultaneous electrochemical determination of CA125 and HE4 biomarkers for the early diagnosis of ovarian cancer.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The blood levels of cancer antigen 125 (CA125) and human epididymal secretory protein 4 (HE4) are measured in the diagnosis and progression monitoring of ovarian cancer (OC), and the Risk of Ovarian Malignancy Algorithm (ROMA) score% values are calculated for cancer risk assessment. For the first time, disposable dual screen-printed carbon electrodes modified with reduced graphene oxide, polythionine, and gold nanoparticles were used to fabricate label-free electrochemical dual CA125-HE4 immunosensors for the sensitive, fast, and practical simultaneous determination of CA125 and HE4. DPV and SWV methods were used to simultaneously determine antigens in two different linear ranges (1-100 pg mL-1 and 1-50 ng mL-1). High sensitivity, low LOD, and LOQ were obtained for two linear ranges with a correlation coefficient above 0.99. The application stability of the dual CA125-HE4 immunosensors was determined as 60 days, and the storage stability was determined as 16 weeks. The dual immunosensors exhibited high selectivity in eight different antigen mixtures. The reusability of the dual immunosensors has been tested up to 9 cycles. ROMA score% values for pre-menopausal and post-menopausal status were calculated using the concentration of CA125 and HE4 in the blood serum and assessing OC risk. The disposable dual immunosensors can be used in point-of-care tests for rapid and practical simultaneous determination of CA125 and HE4 with high selectivity, sensitivity, and repeatability.

          Related collections

          Author and article information

          Journal
          Anal Bioanal Chem
          Analytical and bioanalytical chemistry
          Springer Science and Business Media LLC
          1618-2650
          1618-2642
          Apr 2023
          : 415
          : 9
          Affiliations
          [1 ] Chemistry Department, Faculty of Science, Çankırı Karatekin University, Çankırı, 18100, Turkey. melikebilgikamac@gmail.com.
          [2 ] Chemistry Department, Faculty of Science, Çankırı Karatekin University, Çankırı, 18100, Turkey.
          [3 ] Bioengineering Department, Faculty of Engineering, Çanakkale Onsekiz Mart University, Çanakkale, Turkey. msezginturk@comu.edu.tr.
          Article
          10.1007/s00216-023-04569-y
          10.1007/s00216-023-04569-y
          36719438
          443ee411-927e-42e3-bd1a-c4b973ca70eb
          History

          Simultaneous determination,Ovarian cancer,HE4,Dual electrochemical immunosensors,CA125

          Comments