2
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Maternal glycemic control and hypoglycemia in type 1 diabetic pregnancy: a randomized trial of insulin aspart versus human insulin in 322 pregnant women.

      Diabetes Care
      Adult, Body Mass Index, Diabetes Mellitus, Type 1, blood, drug therapy, Drug Administration Schedule, Europe, Female, Gestational Age, Hemoglobin A, Glycosylated, analysis, Humans, Hypoglycemia, epidemiology, Hypoglycemic Agents, therapeutic use, Insulin, analogs & derivatives, Insulin Aspart, Insulin, Isophane, Pregnancy, Pregnancy Complications, Pregnancy Outcome, Quality of Life

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To assess the safety and efficacy of insulin aspart (IAsp) versus regular human insulin (HI) in basal-bolus therapy with NPH insulin in pregnant women with type 1 diabetes. Subjects (n = 322) who were pregnant or planning pregnancy were randomized to IAsp or HI as meal-time insulin in an open-label, parallel-group, multicenter study. Subjects had A1C < or =8% at confirmation of pregnancy. Insulin doses were titrated toward predefined glucose targets and A1C <6.5%. Outcomes assessed included risk of major maternal hypoglycemia, A1C, plasma glucose profiles, and maternal safety outcomes. Major hypoglycemia occurred at a rate of 1.4 vs. 2.1 episodes/year exposure with IAsp and HI, respectively (relative risk 0.720 [95% CI 0.36-1.46]). Risk of major/major nocturnal hypoglycemia was 52% (RR 0.48 [0.20-1.143]; P = NS) lower with IAsp compared with HI. A1C was comparable with human insulin in second (IAsp-HI -0.04 [-0.18 to 0.11]) and third (-0.08 [-0.23 to 0.06]) trimesters. A total of 80% of subjects achieved an A1C < or =6.5%. At the end of first and third trimesters, average postprandial plasma glucose increments were significantly lower with IAsp than HI (P = 0.003 and P = 0.044, respectively), as were mean plasma glucose levels 90 min after breakfast (P = 0.044 and P = 0.001, respectively). Maternal safety profiles and pregnancy outcomes were similar between treatments. IAsp is at least as safe and effective as HI when used in basal-bolus therapy with NPH insulin in pregnant women with type 1 diabetes and may potentially offer some benefits in terms of postprandial glucose control and preventing severe hypoglycemia.

          Related collections

          Author and article information

          Comments

          Comment on this article