          Abstract

          Metaldehyde is extensively used worldwide as a contact and systemic molluscicide for controlling slugs and snails in a wide range of agricultural and horticultural crops. Contamination of surface waters due to run-off, coupled with its moderate solubility in water, has led to increased concentration of the pesticide in the environment. In this study, for the first time, rapid analysis (<~1 minute) of metaldehyde residues in water is demonstrated using paper spray mass spectrometry (PS-MS). The observed precursor molecular ions of metaldehyde were confirmed from tandem mass spectrometry (MS/MS) experiments by studying the fragmentation patterns produced via collision-induced dissociation. The signal intensity ratios of the most abundant MS/MS transitions for metaldehyde (177 → 149 for protonated ion) and atrazine (221 → 179) were found to be linear in the range 0.01 to 5 ng/mL. Metaldehyde residues were detectable in environmental water samples at low concentration (LOD < 0.1 ng/mL using reactive PS-MS), with a relative standard deviation <10% and an R 2 value >0.99, without any pre-concentration/separation steps. This result is of particular importance for environmental monitoring and water quality analysis providing a potential means of rapid screening to ensure safe drinking water.

          Related collections

          Most cited references43

          • Record: found
          • Abstract: found
          • Article: not found

          Versatile new ion source for the analysis of materials in open air under ambient conditions.

          A new ion source has been developed for rapid, noncontact analysis of materials at ambient pressure and at ground potential. The new source, termed DART (for "Direct Analysis in Real Time"), is based on the reactions of electronic or vibronic excited-state species with reagent molecules and polar or nonpolar analytes. DART has been installed on a high-resolution time-of-flight mass spectrometer (TOFMS) that provides improved selectivity and accurate elemental composition assignment through exact mass measurements. Although DART has been applied to the analysis of gases, liquids, and solids, a unique application is the direct detection of chemicals on surfaces without requiring sample preparation, such as wiping or solvent extraction. DART has demonstrated success in sampling hundreds of chemicals, including chemical agents and their signatures, pharmaceutics, metabolites, peptides and oligosaccharides, synthetic organics, organometallics, drugs of abuse, explosives, and toxic industrial chemicals. These species were detected on various surfaces, such as concrete, asphalt, human skin, currency, airline boarding passes, business cards, fruits, vegetables, spices, beverages, body fluids, horticultural leaves, cocktail glasses, and clothing. DART employs no radioactive components and is more versatile than devices using radioisotope-based ionization. Because its response is instantaneous, DART provides real-time information, a critical requirement for screening or high throughput.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Detection Technologies. Ambient mass spectrometry.

            A recent innovation in mass spectrometry is the ability to record mass spectra on ordinary samples, in their native environment, without sample preparation or preseparation by creating ions outside the instrument. In desorption electrospray ionization (DESI), the principal method described here, electrically charged droplets are directed at the ambient object of interest; they release ions from the surface, which are then vacuumed through the air into a conventional mass spectrometer. Extremely rapid analysis is coupled with high sensitivity and high chemical specificity. These characteristics are advantageously applied to high-throughput metabolomics, explosives detection, natural products discovery, and biological tissue imaging, among other applications. Future possible uses of DESI for in vivo clinical analysis and its adaptation to portable mass spectrometers are described.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Paper spray for direct analysis of complex mixtures using mass spectrometry.

                Bookmark

                Author and article information

                Journal
                Sci Rep
                Sci Rep
                Scientific Reports
                Nature Publishing Group
                2045-2322
                21 October 2016
                2016
                : 6
                : 35643
                Affiliations
                [1 ]Department of Electrical Engineering & Electronics, University of Liverpool , Brownlow Hill, Liverpool, L69 3GJ, UK
                [2 ]Department of Chemistry and Biochemistry, The Ohio State University , Columbus, OH, 43210, USA
                [3 ]Northumbrian Water, Leat House, Pattinson Road , Washington, NE38 8LB, UK
                [4 ]M4I, Maastricht Multimodal Molecular Imaging Institute, Maastricht University, Faculty of Health, Medicine and Life Sciences , Universiteitssingel 50, 6229 ER Maastricht, The Netherlands
                [5 ]Institute of Integrative Biology, University of Liverpool , Crown Street, Liverpool, L69 7ZB, UK
                Author notes
                Article
                srep35643
                10.1038/srep35643
                5073298
                27767044
                2f56a535-da37-40c3-b042-08105375cd40
                Copyright © 2016, The Author(s)

                This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/

                History
                : 07 April 2016
                : 30 September 2016
                Categories
                Article

                Uncategorized
                Uncategorized

                Comments

                Comment on this article