3
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Bedside diagnosis of systolic murmurs.

      The New England journal of medicine
      Adolescent, Adult, Aged, Amyl Nitrite, diagnostic use, Aortic Valve Stenosis, diagnosis, Cardiomyopathy, Hypertrophic, Child, Heart Auscultation, methods, Heart Murmurs, Heart Septal Defects, Ventricular, Humans, Isometric Contraction, Middle Aged, Mitral Valve Insufficiency, Mitral Valve Prolapse, Posture, Respiration, Valsalva Maneuver

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The diagnostic accuracy of bedside maneuvers in the evaluation of patients with systolic murmurs has not been assessed objectively. Therefore, we evaluated 50 patients with documented systolic murmurs and compared all standard bedside techniques. Murmurs originating within the right-sided chambers of the heart were best differentiated from all other murmurs by augmentation of their intensity with inspiration (100 percent sensitivity, 88 percent specificity) and diminution of their intensity with expiration (100 percent sensitivity, 88 percent specificity). The murmur of hypertrophic cardiomyopathy was distinguished from all other murmurs by an increase in intensity with the Valsalva maneuver (65 percent sensitivity, 96 percent specificity) and during squatting-to-standing action (95 percent sensitivity, 84 percent specificity), and by a decrease in intensity during standing-to-squatting action (95 percent sensitivity, 85 percent specificity), passive leg elevation (85 percent sensitivity, 91 percent specificity), and handgrip (85 percent sensitivity, 75 percent specificity). The murmurs of mitral regurgitation and ventricular septal defect had parallel responses to all maneuvers, but could be differentiated from other systolic murmurs by augmentation of their intensity with handgrip (68 percent sensitivity, 92 percent specificity) and during transient arterial occlusion (78 percent sensitivity, 100 percent specificity), and by a decrease in their intensity during the inhalation of amyl nitrite (80 percent sensitivity, 90 percent specificity). No single maneuver identified the murmur of aortic stenosis, but the diagnosis could be made by exclusion. Although no single maneuver is 100 percent accurate in diagnosing the cause of a systolic murmur, its origin can be determined accurately at the bedside by observation of the response to a combination of maneuvers.

          Related collections

          Author and article information

          Comments

          Comment on this article

          scite_
          0
          0
          0
          0
          Smart Citations
          0
          0
          0
          0
          Citing PublicationsSupportingMentioningContrasting
          View Citations

          See how this article has been cited at scite.ai

          scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.

          Similar content175

          Cited by9