      Guide to Microbiological Control in Pharmaceuticals and Medical Devices, Second Edition 

      Sterilization Methods

      edited-book
      ,
      CRC Press

      Read this book at

      Buy book Bookmark
          There is no author summary for this book yet. Authors can add summaries to their books on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references51

          • Record: found
          • Abstract: found
          • Article: not found

          Vapor-phase hydrogen peroxide as a surface decontaminant and sterilant.

          The feasibility of utilizing vapor-phase hydrogen peroxide (VPHP) as a surface decontaminant and sterilant was evaluated in a centrifuge application. The prototype VPHP decontamination system, retrofitted into a Beckman L8-M ultracentrifuge, was designed to vaporize a 30% (wt/wt) solution of aqueous hydrogen peroxide continuously injecting and withdrawing VPHP in a deep-vacuum flow-through system. VPHP cycles of 4, 8, 16, and 32 min were examined for cidal activity against spores of Bacillus subtilis subsp. globigii and Bacillus stearothermophilus. Spore inocula (approximately 10(6)/coupon) were dried onto 0.5-in. (1.27-cm)-square stainless-steel coupons, and coupons were suspended in the centrifuge chamber, the space between the refrigeration can and the barrier ring (inner gap), and the space between the barrier ring and the vacuum ring (outer gap). At a chamber temperature of 4 degrees C, B. subtilis subsp. globigii spores were inactivated within 8 min, while inactivation of spores located in the outer gap at 27 degrees C required 32 min. The elevated temperature and high surface area/volume ratios in the outer gap may serve to decompose the gas more rapidly, thus reducing cidal efficacy. Of the two test spores, B. stearothermophilus was more resistant to VPHP. Nonetheless, VPHP was shown to possess significant sporicidal capability. For practical decontamination applications of the type described, VPHP shows promise as an effective and safer alternative to currently used ethylene oxide or formaldehyde vapors.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            The combined effect of hydrogen peroxide and ultraviolet irradiation on bacterial spores.

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Asthma and rhinitis after exposure to glutaraldehyde in endoscopy units.

              Four nurses working in endoscopy units complained of respiratory symptoms on exposure to alkaline glutaraldehyde used as a disinfectant for fibre-optic endoscopes. A provocation test was positive in two of these patients. This is the first report to use provocation testing to confirm a relation between exposure to alkaline glutaraldehyde and respiratory disease.