      Multicenter evaluation of a new inosine monophosphate dehydrogenase inhibition assay for quantification of total mycophenolic acid in plasma.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The performance characteristics of a new inosine monophosphate dehydrogenase inhibition assay for the quantification of total mycophenolic acid (MPA) in plasma (Roche Diagnostics) were assessed in a multicenter evaluation. Validation data were collected from four institutions. Within-run and total imprecision were acceptable (n = 21 for each of 7 materials, coefficients of variation ranging 0.7-9.6%). The lower limit of quantification was 0.31 mg/L. The assay was linear from 0.31 to 15.0 mg/L. Method comparison with validated high-performance liquid chromatography with ultraviolet light or liquid chromatography tandem mass spectrometry methods showed good agreement (coefficients of correlation 0.974-0.994, slopes 1.01-1.17, intercepts -0.17 to 0.06). There was no difference found between results from different transplant types (cardiac vs. renal) or comedications (cyclosporine vs. tacrolimus). The recovery of samples from a proficiency testing scheme was acceptable. The cross-reactivity of AcMPAG, an in vitro active metabolite of MPA, was examined by adding AcMPAG to a pool of patient samples and subsequent quantification. MPA overestimation by AcMPAG cross-reactivity was found to be low (<5%). Thus, this interference is expected to be clinically irrelevant. In conclusion, the Roche Total MPA assay is a promising alternative for MPA quantification where chromatographic methods are not available.

          Related collections

          Author and article information

          Journal
          Ther Drug Monit
          Therapeutic drug monitoring
          Ovid Technologies (Wolters Kluwer Health)
          0163-4356
          0163-4356
          Aug 2008
          : 30
          : 4
          Affiliations
          [1 ] Department of Clinical Chemistry, University Hospital Goettingen, Germany. gunnar.brandhorst@med.uni-goettingen.de
          Article
          10.1097/FTD.0b013e31817fd590
          18641549
          c7f127da-8a74-4755-af07-513079dacb03
          History

          Comments

          Comment on this article