      Development of a novel self-sanitizing mask prototype to combat the spread of infectious disease and reduce unnecessary waste

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          With the spread of COVID-19, significant emphasis has been placed on mitigation techniques such as mask wearing to slow infectious disease transmission. Widespread use of face coverings has revealed challenges such as mask contamination and waste, presenting an opportunity to improve the current technologies. In response, we have developed the Auto-sanitizing Retractable Mask Optimized for Reusability (ARMOR). ARMOR is a novel, reusable face covering that can be quickly disinfected using an array of ultraviolet C lamps contained within a wearable case. A nanomembrane UVC sensor was used to quantify the intensity of germicidal radiation at 18 different locations on the face covering and determine the necessary exposure time to inactivate SARS-CoV-2 in addition to other viruses and bacteria. After experimentation, it was found that ARMOR successfully provided germicidal radiation to all areas of the mask and will inactivate SARS-CoV-2 in approximately 180 s, H1N1 Influenza in 130 s, and Mycobacterium tuberculosis in 113 s, proving that this design is effective at eliminating a variety of pathogens and can serve as an alternative to traditional waste-producing disposable face masks. The accessibility, ease of use, and speed of sanitization supports the wide application of ARMOR in both clinical and public settings.

          Related collections

          Most cited references14

          • Record: found
          • Abstract: found
          • Article: not found

          Aerosol and Surface Stability of SARS-CoV-2 as Compared with SARS-CoV-1

          To the Editor: A novel human coronavirus that is now named severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) (formerly called HCoV-19) emerged in Wuhan, China, in late 2019 and is now causing a pandemic. 1 We analyzed the aerosol and surface stability of SARS-CoV-2 and compared it with SARS-CoV-1, the most closely related human coronavirus. 2 We evaluated the stability of SARS-CoV-2 and SARS-CoV-1 in aerosols and on various surfaces and estimated their decay rates using a Bayesian regression model (see the Methods section in the Supplementary Appendix, available with the full text of this letter at NEJM.org). SARS-CoV-2 nCoV-WA1-2020 (MN985325.1) and SARS-CoV-1 Tor2 (AY274119.3) were the strains used. Aerosols (<5 μm) containing SARS-CoV-2 (105.25 50% tissue-culture infectious dose [TCID50] per milliliter) or SARS-CoV-1 (106.75-7.00 TCID50 per milliliter) were generated with the use of a three-jet Collison nebulizer and fed into a Goldberg drum to create an aerosolized environment. The inoculum resulted in cycle-threshold values between 20 and 22, similar to those observed in samples obtained from the upper and lower respiratory tract in humans. Our data consisted of 10 experimental conditions involving two viruses (SARS-CoV-2 and SARS-CoV-1) in five environmental conditions (aerosols, plastic, stainless steel, copper, and cardboard). All experimental measurements are reported as means across three replicates. SARS-CoV-2 remained viable in aerosols throughout the duration of our experiment (3 hours), with a reduction in infectious titer from 103.5 to 102.7 TCID50 per liter of air. This reduction was similar to that observed with SARS-CoV-1, from 104.3 to 103.5 TCID50 per milliliter (Figure 1A). SARS-CoV-2 was more stable on plastic and stainless steel than on copper and cardboard, and viable virus was detected up to 72 hours after application to these surfaces (Figure 1A), although the virus titer was greatly reduced (from 103.7 to 100.6 TCID50 per milliliter of medium after 72 hours on plastic and from 103.7 to 100.6 TCID50 per milliliter after 48 hours on stainless steel). The stability kinetics of SARS-CoV-1 were similar (from 103.4 to 100.7 TCID50 per milliliter after 72 hours on plastic and from 103.6 to 100.6 TCID50 per milliliter after 48 hours on stainless steel). On copper, no viable SARS-CoV-2 was measured after 4 hours and no viable SARS-CoV-1 was measured after 8 hours. On cardboard, no viable SARS-CoV-2 was measured after 24 hours and no viable SARS-CoV-1 was measured after 8 hours (Figure 1A). Both viruses had an exponential decay in virus titer across all experimental conditions, as indicated by a linear decrease in the log10TCID50 per liter of air or milliliter of medium over time (Figure 1B). The half-lives of SARS-CoV-2 and SARS-CoV-1 were similar in aerosols, with median estimates of approximately 1.1 to 1.2 hours and 95% credible intervals of 0.64 to 2.64 for SARS-CoV-2 and 0.78 to 2.43 for SARS-CoV-1 (Figure 1C, and Table S1 in the Supplementary Appendix). The half-lives of the two viruses were also similar on copper. On cardboard, the half-life of SARS-CoV-2 was longer than that of SARS-CoV-1. The longest viability of both viruses was on stainless steel and plastic; the estimated median half-life of SARS-CoV-2 was approximately 5.6 hours on stainless steel and 6.8 hours on plastic (Figure 1C). Estimated differences in the half-lives of the two viruses were small except for those on cardboard (Figure 1C). Individual replicate data were noticeably “noisier” (i.e., there was more variation in the experiment, resulting in a larger standard error) for cardboard than for other surfaces (Fig. S1 through S5), so we advise caution in interpreting this result. We found that the stability of SARS-CoV-2 was similar to that of SARS-CoV-1 under the experimental circumstances tested. This indicates that differences in the epidemiologic characteristics of these viruses probably arise from other factors, including high viral loads in the upper respiratory tract and the potential for persons infected with SARS-CoV-2 to shed and transmit the virus while asymptomatic. 3,4 Our results indicate that aerosol and fomite transmission of SARS-CoV-2 is plausible, since the virus can remain viable and infectious in aerosols for hours and on surfaces up to days (depending on the inoculum shed). These findings echo those with SARS-CoV-1, in which these forms of transmission were associated with nosocomial spread and super-spreading events, 5 and they provide information for pandemic mitigation efforts.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            Far-UVC light (222 nm) efficiently and safely inactivates airborne human coronaviruses

            A direct approach to limit airborne viral transmissions is to inactivate them within a short time of their production. Germicidal ultraviolet light, typically at 254 nm, is effective in this context but, used directly, can be a health hazard to skin and eyes. By contrast, far-UVC light (207–222 nm) efficiently kills pathogens potentially without harm to exposed human tissues. We previously demonstrated that 222-nm far-UVC light efficiently kills airborne influenza virus and we extend those studies to explore far-UVC efficacy against airborne human coronaviruses alpha HCoV-229E and beta HCoV-OC43. Low doses of 1.7 and 1.2 mJ/cm2 inactivated 99.9% of aerosolized coronavirus 229E and OC43, respectively. As all human coronaviruses have similar genomic sizes, far-UVC light would be expected to show similar inactivation efficiency against other human coronaviruses including SARS-CoV-2. Based on the beta-HCoV-OC43 results, continuous far-UVC exposure in occupied public locations at the current regulatory exposure limit (~3 mJ/cm2/hour) would result in ~90% viral inactivation in ~8 minutes, 95% in ~11 minutes, 99% in ~16 minutes and 99.9% inactivation in ~25 minutes. Thus while staying within current regulatory dose limits, low-dose-rate far-UVC exposure can potentially safely provide a major reduction in the ambient level of airborne coronaviruses in occupied public locations.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Face Mask and Medical Waste Disposal during the Novel COVID-19 Pandemic in Asia

              The origin of the novel human coronavirus (SARS-CoV-2) and its potential for harm increased face mask and medical waste in the environment, thereby necessitating the urgent prevention and control of the pandemic. The article estimates the face mask and medical waste generation in Asia during the pandemic to convince the waste management and scientific communities to find ways to address the negative impact that the waste disposal has on the environment. Standardisation, procedures, guidelines and strict implementation of medical waste management related to COVID-19, community habitats and public areas should be carefully considered to reduce pandemic risks in hospitals, as proper medical waste disposal effectively controls infection sources.
                Bookmark

                Author and article information

                Contributors
                hwan.choi@ucf.edu
                Journal
                Sci Rep
                Sci Rep
                Scientific Reports
                Nature Publishing Group UK (London )
                2045-2322
                14 September 2021
                14 September 2021
                2021
                : 11
                : 18213
                Affiliations
                [1 ]GRID grid.170430.1, ISNI 0000 0001 2159 2859, Department of Biomedical Sciences, , University of Central Florida, ; Orlando, 32816 USA
                [2 ]GRID grid.170430.1, ISNI 0000 0001 2159 2859, Department of Mechanical and Aerospace Engineering, , University of Central Florida, ; Orlando, 32816 USA
                [3 ]GRID grid.170430.1, ISNI 0000 0001 2159 2859, Department of Electrical and Computer Engineering, , University of Central Florida, ; Orlando, 32816 USA
                [4 ]Tehran, Iran
                Article
                97357
                10.1038/s41598-021-97357-6
                8440541
                a0542d48-6e54-4d35-a4cd-4febd6cf0d30
                © The Author(s) 2021

                Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

                History
                : 10 June 2021
                : 23 August 2021
                Categories
                Article
                Custom metadata
                © The Author(s) 2021

                Uncategorized
                biomedical engineering,mechanical engineering
                Uncategorized
                biomedical engineering, mechanical engineering

                Comments

                Comment on this article